8
8
8-40
8-40
Service Mode > COPIER > DISPLAY > DENS
Service Mode > COPIER > DISPLAY > DENS
COPIER > DISPLAY > DENS
D-C-TRGT
Dspl of ATR ctrl C patch target density
Lv.2 Details
To display the target density for C patch image created by ATR
control.
Use case
When analyzing the cause of a problem
Display/adj/set range
0 to 1023
Appropriate target value 300 to 700
REF-Y
Dspl of Y developer density target value
Lv.1 Details
To display the developer density target value for the ATR Sensor (Y).
Use case
When analyzing the cause of a problem
Display/adj/set range
0 to 255
Appropriate target value 20 to 230
REF-M
Dspl of M developer density target value
Lv.1 Details
To display the developer density target value for the ATR Sensor (M).
Use case
When analyzing the cause of a problem
Display/adj/set range
0 to 255
Appropriate target value 20 to 230
REF-C
Dspl of C developer density target value
Lv.1 Details
To display the developer density target value for the ATR Sensor (C).
Use case
When analyzing the cause of a problem
Display/adj/set range
0 to 255
Appropriate target value 20 to 230
REF-K
Dspl Bk developer density target value
Lv.1 Details
To display the developer density target value for the ATR Sensor (Bk).
Use case
When analyzing the cause of a problem
Display/adj/set range
0 to 255
Appropriate target value 20 to 230
SGNL-Y
Display of Y-color developer density
Lv.1 Details
To display the measured value of Y-color developer density.
The density is measured with the ATR Sensor (Y) for each job.
The value is updated upon print operation after power-on.
Use case
When analyzing the cause of a problem
Display/adj/set range
0 to 255
Appropriate target value 20 to 230
Related service mode
COPIER> DISPLAY> DENS> DENS-Y
SGNL-M
Display of M-color developer density
Lv.1 Details
To display the measured value of M-color developer density.
The density is measured with the ATR Sensor (M) for each job.
The value is updated upon print operation after power-on.
Use case
When analyzing the cause of a problem
Display/adj/set range
0 to 255
Appropriate target value 20 to 230
Related service mode
COPIER> DISPLAY> DENS> DENS-M
COPIER > DISPLAY > DENS
SGNL-C
Display of C-color developer density
Lv.1 Details
To display the measured value of C-color developer density.
The density is measured with the ATR Sensor (C) for each job.
The value is updated upon print operation after power-on.
Use case
When analyzing the cause of a problem
Display/adj/set range
0 to 255
Appropriate target value 20 to 230
Related service mode
COPIER> DISPLAY> DENS> DENS-C
SGNL-K
Display of Bk-color developer density
Lv.1 Details
To display the measured value of Bk-color developer density.
The density is measured with the ATR Sensor (Bk) for each job.
The value is updated upon print operation after power-on.
Use case
When analyzing the cause of a problem
Display/adj/set range
0 to 255
Appropriate target value 20 to 230
Related service mode
COPIER> DISPLAY> DENS> DENS-K
P-SENS-P
Dspl base intnsty at ATR ctrl (P-wave)
Lv.2 Details
To display the light intensity (P-wave) reflected from the background
(ITB) at ATR control.
Intolerable values may be caused by Patch Sensor disconnection,
LED failure, soiled Sensor surface, Shutter failure, Registration Patch
Shutter Open/Close Solenoid failure, insufficient ITB cleaning, etc.
Use case
When checking the failure of Patch Sensor/ITB at low density,
fogging deterioration or E020 display
Display/adj/set range
0 to 1023
Appropriate target value 400 to 1000
Related service mode
COPIER> DISPLAY> DENS> P-SENS-S
DEV-DC-Y
Dspl of developing DC voltage (Y)
Lv.2 Details
To display the latest Y developing DC voltage Vdc.
Use case
- When image failure occurs due to carrier adherence
- When fogging occurs
- When fogging is deteriorated
Display/adj/set range
-800 to -200
Unit
V
Appropriate target value -800 to -200
DEV-DC-M
Dspl of developing DC voltage (M)
Lv.2 Details
To display the latest M developing DC voltage Vdc.
Use case
- When image failure occurs due to carrier adherence
- When fogging occurs
- When fogging is deteriorated
Display/adj/set range
-800 to -200
Unit
V
Appropriate target value -800 to -200
Содержание IMAGERUNNER ADVANCE C5030
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 259: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts ...
Страница 450: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 575: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Страница 701: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...