7
7
7-4
7-4
Error■Code■>■Error■Code■>■Error■Code■Details
Error■Code■>■Error■Code■>■Error■Code■Details
Error■Code
Error■Code■Details
E■
code
Detail■
code
Location
Items
Description
E001 0000
05
Title
Abnormal■high■temperature■in■Main■Thermistor■1,■2
Description Main■Thermistor■1,■2■(TH1)■detects■260■deg■C■or■more■for■0.2■
sec.
Remedy
1.■Go■through■the■following:■DISPLAY■>■ANALOG■>■
FIX-C,■or■DISPLAY■>■ANALOG■>■FIX-E;■if■it’s■less■than■
260■deg■C,■go■through■the■following■to■clear■the■error:■
COPIER>FUNCTION>CLEAR>ERR;■and■then■turn■OFF/ON■
the■power.■
It■it’s■260■deg■C■or■more,■do■not■turn■on■the■power■before■
replacing■the■Film■Unit.■
2.■Replace■the■Film■Unit.■
3.■Replacement■of■the■Shutter■Unit■
4.■Replace■the■DC■Controller■PCB■(UN1).■
■
NOTE:■After■performing■the■above■remedy■work,■go■through■
the■following■to■clear■the■error:■COPIER■>■FUNCTION■>■
CLEAR■>■ERR
E001 0001
05
Title
Abnormal■high■temperature■in■Sub■Thermistor■1,■2
Description Sub■Thermistor■1,■2■(TH1)■detects■275■deg■C■or■more■for■0.2■
sec.
Remedy
1.■Go■through■the■following:■DISPLAY■>■ANALOG■>■FIX-E2■
or■DISPLAY■>■ANALOG■>■FIX-E3;■if■it’s■less■than■275■deg■
C,■go■through■the■following■to■clear■the■error:■COPIER■>■
FUNCTION■>■CLEAR■>■ERR;■and■then■turn■OFF■and■then■
ON■the■power.■
If■it’s■275■deg■C■or■more,■do■not■turn■on■the■power■before■
replacing■the■Film■Unit.■
2.■Replace■the■Film■Unit■
3.■Replacement■of■the■Shutter■Unit■
4.■Go■through■the■following■to■check■drive■of■FM5■and■FM6:■
COPIER■>■FUNCTION■>■PART-CHK■>■FAN;■if■not■working■
properly,■replace■the■fan.■
5.■Replace■the■DC■Controller■PCB■(UN1)■
■
NOTE:■After■performing■the■above■remedy■work,■go■through■
the■following■to■clear■the■error:■COPIER■>■FUNCTION■>■
CLEAR■>■ERR
E■
code
Detail■
code
Location
Items
Description
E001 0003
05
Title
High■temperature■error■detected■by■hardware
Description Hardware■detects■abnormal■high■temperature■of■the■
Thermistor■(Main■Thermistor■1:■264■deg■C,■Main■Thermistor■
2:■265■deg■C,■Sub■Thermistor■1,■2:■280■deg■C)■for■400■msec■
consecutively.
Remedy
1.■If■the■detected■temperature■of■the■Thermistor■is■less■than■
the■abnormal■high■temperature■specified■for■Thermistor,■
go■through■the■following■to■clear■the■error:■COPIER■>■
FUNCTION■>■CLEAR■>■ERR;■and■then■turn■OFF■and■then■
ON■the■power.■
If■it’s■at■abnormally■high■temperature,■do■not■turn■on■the■
power■before■replacing■the■Film■Unit.■
2.■Replace■the■Film■Unit■
3.■Replacement■of■the■Shutter■Unit■
4.■Go■through■the■following■to■check■drive■of■FM5■and■
FM6:■COPIER■>■FUNCTION■>■PART-CHK■>■FAN;■if■the■not■
working■properly,■replace■the■fan.■
5.■Replace■the■DC■Controller■PCB■(UN1)■
■
NOTE:■After■performing■the■above■remedy■work,■go■through■
the■following■to■clear■the■error:■COPIER■>■FUNCTION■>■
CLEAR■>■ERR
E003 0000
05
Title
Error■detected■when■the■Heater■is■ON
Description After■the■Heater■was■turned■ON,■Main■Thermistor■2,■Sub■
Thermistor■1■or■Sub■Thermistor■2■detects■20■deg■C■or■more■
and■50■deg■C■or■less■for■3■sec.
Remedy
1.■Go■through■the■following■to■clear■the■error:■COPIER■>■
FUNCTION■>■CLEAR■>■ERR;■and■then■turn■OFF■and■then■
ON■the■power.■
2.■Check■connection■of■the■Connectors■(Thermistor■
Connector■and■AC■Connector).■
3.■Replace■the■Film■Unit■
4.■Replacement■of■the■Shutter■Unit■
5.■Replace■the■DC■Controller■PCB■(UN1)■
■
NOTE:■After■performing■the■above■remedy■work,■go■through■
the■following■to■clear■the■error:■COPIER■>■FUNCTION■>■
CLEAR■>■ERR
Содержание IMAGERUNNER ADVANCE C5030
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 259: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts ...
Страница 450: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 575: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Страница 701: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...