Service Mode > COPIER > DISPLAY > HT-C
Service Mode > COPIER > DISPLAY > HT-C
COPIER > DISPLAY > HT-C
SGL-A-Y3
ARCDAT scrnA Y-patch current VL(1/3 SPD)
Lv.2 Details
To display the current Y-patch value of screen A in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-A-M3
ARCDAT scrnA M-patch current VL(1/3 SPD)
Lv.2 Details
To display the current M-patch value of screen A in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-A-C3
ARCDAT scrnA C-patch current VL(1/3 SPD)
Lv.2 Details
To display the current C-patch value of screen A in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-A-K3
ARCDAT scrnA Bk-patch current VL(1/3SPD)
Lv.2 Details
To display the current Bk-patch value of screen A in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-B-Y3
ARCDAT scrnB Y-patch current VL(1/3 SPD)
Lv.2 Details
To display the current Y-patch value of screen B in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-B-M3
ARCDAT scrnB M-patch current VL(1/3 SPD)
Lv.2 Details
To display the current M-patch value of screen B in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
COPIER > DISPLAY > HT-C
SGL-B-C3
ARCDAT scrnB C-patch current VL(1/3 SPD)
Lv.2 Details
To display the current C-patch value of screen B in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-B-K3
ARCDAT scrnB Bk-patch current VL(1/3SPD)
Lv.2 Details
To display the current Bk-patch value of screen B in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-C-Y3
ARCDAT scrnC Y-patch current VL(1/3 SPD)
Lv.2 Details
To display the current Y-patch value of screen C in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-C-M3
ARCDAT scrnC M-patch current VL(1/3 SPD)
Lv.2 Details
To display the current M-patch value of screen C in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-C-C3
ARCDAT scrnC C-patch current VL(1/3 SPD)
Lv.2 Details
To display the current C-patch value of screen C in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-C-K3
ARCDAT scrnC Bk-patch current VL(1/3SPD)
Lv.2 Details
To display the current Bk-patch value of screen C in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
T-8-12
Содержание IMAGERUNNER ADVANCE C5030
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 259: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts ...
Страница 450: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 575: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Страница 701: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...