4
4
4-109
4-109
Parts Replacement and Cleaning > Image Formation System > Reinstalling the ITB > Actions after Replacement
Parts Replacement and Cleaning > Image Formation System > Reinstalling the ITB > Actions after Replacement
CAUTION:
When replacing ITB with a new one, affix the label to the specific position near the
Waste Toner Ejection Mouth of the ITB Cleaning Unit after the ITB Unit is installed.
When affixing the new label, be sure to remove the old label and replace with the new
one on the same position.
■
Actions after Replacement
1) Turn ON the power of the host machine.
2) When the machine is in standby condition, execute the “Auto gradation correction”.
3) Execute the ITB equilibrium position detection in service mode (COPIER > FUNCTION >
MISC-P > ITB-INT). This service mode will take approx. 2 to 3 minutes.