4
4
4-100
4-100
Parts Replacement and Cleaning > Image Formation System > Removing the Primary Transfer Roller (C,M,Y) > Procedure
Parts Replacement and Cleaning > Image Formation System > Removing the Primary Transfer Roller (C,M,Y) > Procedure
CAUTION:
Hold the stopper with finger lightly after installation to check that the claw is surely
installed.
■
Actions after Replacement
1) To execute the ITB Equilibrium Position Detection, make the main body in standby state.
2) Execute the ITB Equilibrium Position Detection Service Mode (COPIER>FUNCTION>MISC-
P>ITB-INIT) (Level 1). This service mode will take approx. 2 to 3 minutes.
Removing the Primary Transfer Roller (C,M,Y)
■
Preparations
1) Open the Front Cover, Right Lower Cover and Right Upper Cover.
2) Remove the ITB Cover.
3) Remove the ITB Unit.
4) Remove the ITB Cleaning Unit.
5) Remove the ITB.
■
Procedure
NOTE:
This procedure describes the steps for Primary Transfer Roller (C). Go through the
same procedure for M and Y.
CAUTION:
Do not touch the surface of Drive Roller, Secondary Transfer Inner Roller and Primary
Transfer Roller as it may cause the image failure.
Содержание IMAGERUNNER ADVANCE C5030
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 259: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts ...
Страница 450: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 575: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Страница 701: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...