Chapter 5: Installation
221
Mount t he Sur g e Sup p r essor
PMP/ PTP 4 50 i/ 4 50 b Series
Gigabit Ethernet Surge Suppressors are installed at both ends of the drop cable. One within 600 mm (24”)
of and under the ODU. The other located within 600 mm (24”) of the building entry point.
Quick procedure:
The quick procedure for the Surge Suppressor for PMP/PTP 450i/450b Series mounting is as follows:
1
Ground using the terminal on the back of the units. Use the
supplied Tubular Lug and 6 mm2 (10 AWG) stranded cable,
max length 600 mm (24”).
l
Waterproof the cable lug with heat shrink sleeving.
l
Secure the Cable assembly to the unit using the
supplied screw and washer.
2
Mount the Gigabit Ethernet Surge Suppressor on the wall
or pole
3
Connect the two CAT5e cables to the Gigabit Ethernet
Surge Suppressor