Chapter 5: Installation
242
Figure 104 :
Rear strap connected to upper AP antenna bracket
5
Attach the entire upper bracket to the antenna using (2) hex bolts, (2) flat washers and (2) lock
washers. Feed the bolt through the lock washer then flat washer, then thread the bolt into the upper
bracket’s threaded receptacle.
Figure 105 :
Assembled upper bracket connected to AP antenna
Note
Use shielded cable for all infrastructure connections associated with APs, SMs, and
CMMs. The environment that these modules operate in often has significant unknown or
varying RF energy. Operator experience consistently indicates that the additional cost
of shielded cables is more than compensated by predictable operation and reduced
costs for troubleshooting and support.
6
Begin assembling the lower bracket by attaching the (2) 7” hex bolts to the bracket using (2)
Содержание PMP 450 Series