User Guide
98
www.bull.com
Manual Rebuild
1.
Replace a hard disk drive and turn on the server.
2.
Run the LSI Software Raid Configuration Utility.
3.
Select "Rebuild" from the TOP menu.
The "Rebuild – PHYSICAL DRIVES SELECTION MENU" screen appears.
Figure 42: Physical Drives Selection menu
4.
Move the cursor onto the hard disk drive displaying "FAIL" and then press
Space
to select it.
Multiple hard disk drives can be selected (simultaneous rebuilding.)
5.
The "FAIL" indication for the hard disk drive selected starts blinking.
6.
When the hard disk drive has been selected, press
F10
to start rebuilding.
7.
Press "Yes" when prompted for confirmation.
The Rebuild process starts.
Replace hard disk drive
Run LSI Software Raid Configuration Utility
Execute rebuilding
Exit LSI Software Raid Configuration Utility