User Guide
86
www.bull.com
Hot-Swap
The hot-swap enables a HDD to be removed (or replaced) under system operation.
Hot-Spare
The hot-spare is prepared as an auxiliary HDD substituting for a defective HDD
included in a virtual drive which is configured at a redundant RAID level. Detecting a
HDD fault, the system disconnects the HDD (or makes it offline) and starts Rebuild
using the hot-spare.
RAID Levels
The table below lists the characteristics of the RAID levels.
Caution
To use RAID 5 or RAID 6 with Internal RAID Controller, you
need to install the optional RAID Upgrade Kit.
Figure 33: RAID Levels Characteristics
Level
Function
Redundancy
Characteristics
RAID 0
Striping
No
Data read/write at the highest rate
Largest capacity
Capacity: (capacity of single HDD) × (number
of HDDs)
RAID 1
Mirroring
Yes
Two HDDs required
Capacity: capacity of single HDD
RAID 5
Striping of both data
and redundant data
Yes
Three or more HDDs required
Capacity: (capacity of single HDD) × ((number
of HDDs) - 1)
RAID 6
Striping of both data
and redundant data
Yes
Three or more HDDs required
Capacity: (capacity of single HDD) × ((number
of HDDs) - 2)
Содержание NovaScale R440 E1
Страница 1: ...NovaScale R440 E1 User s Guide NOVASCALE REFERENCE 86 A1 83EV 00...
Страница 2: ......
Страница 54: ...User Guide 53 www bull com K Keyboard L Mouse 1 100BASE T 1000BASE TX 10BASE T 2 100BASE T 1000BASE TX 10BASE T...
Страница 69: ...User Guide 68 www bull com Note The BIOS may display more options that presented here...
Страница 315: ...User Guide 314 www bull com 3 Follow the on screen messages to proceed with the activation...
Страница 365: ......
Страница 366: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 83EV 00...