Installing and Removing a Hard Disk Drive
The hard disk drive bay at the front of the server chassis may contain hard disk drives
of approximately 25.4 mm (1 inch) high.
The disk interface, number and size of hard disk drives depend on server model, as
described below. The IDs of hard disk drive (channel numbers or port numbers) are
also predefined.
3.5-inch Disk Model
SATA hard disk drive
The serial ATA (SATA) interface is suppported by the following RAID controllers:
- Onboard RAID Controller (LSI Embedded MegaRAID)
- LSILogic MegaRAID SAS 8480E Controller
- Disk Array Controller (SAS/SATA HW RAID0/1)
- Disk Array Controller (SAS/SATA HW RAID5/6)
Up to three hard disk drives (mounted on the dedicated 3.5-inch width tray) can be
installed.
Caution
Do not use any hard disks that are not approved by your sales
representative. Installing a third-party hard disk may cause a
failure of the server as well as the hard disk. Purchase hard
disks of the following models:
- 80 GB, 7,200 rpm, serial ATA2/300
- 160 GB, 7,200 rpm, serial ATA2/300
- 250 GB, 7,200 rpm, serial ATA2/300
- 500 GB, 7,200 rpm, SATA2/300
- 750 GB, 7,200 rpm, SATA2/300
Figure 98: SATA hard disk drive bays
Port 0
Port 1
Port 2
Содержание NovaScale R440 E1
Страница 1: ...NovaScale R440 E1 User s Guide NOVASCALE REFERENCE 86 A1 83EV 00...
Страница 2: ......
Страница 54: ...User Guide 53 www bull com K Keyboard L Mouse 1 100BASE T 1000BASE TX 10BASE T 2 100BASE T 1000BASE TX 10BASE T...
Страница 69: ...User Guide 68 www bull com Note The BIOS may display more options that presented here...
Страница 315: ...User Guide 314 www bull com 3 Follow the on screen messages to proceed with the activation...
Страница 365: ......
Страница 366: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 83EV 00...