Removal
To remove the CPU, prepare the removal referring to steps 1 and 12 in the installation
procedure and do the reverse procedure of steps 17 to 9.
Caution
■
Do not remove any CPU unless it is failed.
■
After the operation, heat may make the cool seat at the bot-
tom of the heat sink adhere to the CPU. To remove the heat
sink from the CPU, first turn the heat sink to the left and right
slightly to make sure that the heat sink can be apart from the
CPU. Removing the heat sink with it adhering to the CPU
may cause the CPU and/or socket to be defected.
Figure 136: Removing the Heat Sink
Do the following procedure if a CPU is removed (or replaced).
1.
Start BIOS Setup to select menus "Main" – "Processor Settings" – "Processor
Retest" in the order to clear the error information on the removed CPU (see
“BIOS Setup Utility” on page 63
).
When a CPU is replaced, select menus "Main" – "Processor Settings" to check
that the ID and L2 Cache of the additional CPU are defined normally (see
“BIOS Setup Utility” on page 63
2.
Set "Reset Configuration Data" on the Advanced menu to "Yes."
This is required to update the hardware configuration information. See
for details.
Содержание NovaScale R440 E1
Страница 1: ...NovaScale R440 E1 User s Guide NOVASCALE REFERENCE 86 A1 83EV 00...
Страница 2: ......
Страница 54: ...User Guide 53 www bull com K Keyboard L Mouse 1 100BASE T 1000BASE TX 10BASE T 2 100BASE T 1000BASE TX 10BASE T...
Страница 69: ...User Guide 68 www bull com Note The BIOS may display more options that presented here...
Страница 315: ...User Guide 314 www bull com 3 Follow the on screen messages to proceed with the activation...
Страница 365: ......
Страница 366: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 83EV 00...