User Guide
141
www.bull.com
6.
Click [Home] at the lower left of the Virtual Disks screen to return to the Top
Menu.
Figure 84: Virtual Disks Screen
Caution
Click [Home] while a background task such as Consistency
Check, Rebuild, or Reconstruction is being executed. If the
progress indication is displayed, the background task may pro-
cess at a slower rate.
Manual Rebuild
The procedure below is based on the following assumption:
One of the HDDs failed in a RAID5 virtual disk configured with three HDDs.
Replace the failed HDD with a new one after turning off the power of the server. The
Auto Rebuild feature is disabled for non-hot-swap replacement. Use the Manual
Rebuild feature to recover the virtual disk as described below.
1.
Start WebBIOS.
Make sure that the status for the replaced HDD is indicated as "UNCONF
GOOD" in the right frame of the Top Menu.