Disk Access Lamp

The DISK ACCESS lamp indicates the status of the hard disk mounted in the 3.5-inch
disk bay.

The lamp turns green each time access is made to the hard disk.

When the DISK ACCESS lamp turns amber, it indicates that a hard disk failure has
occurred.  Check the hard disk lamp for the status of the failing hard disk.

ACT Lamp

The ACT lamp is green while the server is connected to the LAN. The lamp flashes
while the server is accessed via the LAN (during transmission/reception of packets).
The number next to the icon indicates the network port number on the rear panel of the
server.

UID Lamp (UID)

Pressing the UID switch toggles the front panel UID lamp (blue) and the motherboard
UID lamp on and off. The motherboard UID lamp is visible through the rear of the
chassis and allows you to locate the server you're working on from the rear of the
servers on a rack.

Refer to 

“Identification of Servers ~ UID Switch ~” on page 26

 for more information

on the UID switch.

Disk Access Lamp

The disk access lamp of the optical device drive is on while the drive is accessed.

Flashing 
(amber)*

One of the following problems was detected in 
the redundant power configuration:

- AC power is not supplied to one of the two 
power units

- Failure of one of the two power units.

Connect the power cord to supply power. 

If the power supply unit is faulty, contact your 
service representative;

A fan alarm was detected.

Check if the fan units are firmly connected.

If the status lamp indication does not change 
when the fans are normal, contact your sales 
representative.

A temperature warning was detected.

Check if the internal fans are clean and if the 
fan units are firmly connected.

If the status lamp indication does not change 
when the fans are normal, contact your sales 
representative.

A voltage warning was detected

Contact your service representative.

An error was detected on one of the hard disk 
drives.

Table 36: Status Lamp Indications (Continued)

Содержание NovaScale R440 E1

Страница 1: ...NovaScale R440 E1 User s Guide NOVASCALE REFERENCE 86 A1 83EV 00...

Страница 2: ......

Страница 3: ...NOVASCALE NovaScale R440 E1 User s Guide Hardware January 2008 BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 83EV 00...

Страница 4: ...product may vary the suitability of specific product configurations and applications must be determined by the customer and is not warranted by Bull Trademarks NEC ESMPRO NEC DianaScope NEC MWA and E...

Страница 5: ...ndling 18 System Overview 19 Server Chassis 20 External View 20 Front View with Front Bezel Closed 21 Front View with Front Bezel Removed 22 Rear View 24 Internal View 3 5 inch Disk with Non redundant...

Страница 6: ...ew 65 Main Menu 66 Advanced Menu 69 Security Menu 73 Server Menu 75 Boot Menu 81 Exit Menu 82 RAID Configuration 83 RAID 83 Configuration by Onboard RAID Controller 3 5 inch Disk Model 89 Installing t...

Страница 7: ...166 Notes on replacing Hard Disk Drives in a RAID Configuration 169 Installing and Replacing a Power Supply Unit Redundant Power Supply Models 170 Installing a Power Supply Unit 170 Replacing a Faili...

Страница 8: ...emory Dump 234 Preparing for Memory Dumping 234 Saving the Dump File 234 Recovery for Windows Server 2003 x64 Editions and Windows Server 2003 235 Maintenance Tools 235 Maintenance Tools with Remote C...

Страница 9: ...blems Settings 289 Memory Dump Debug Information 289 Windows Dr Watson 291 Network Monitor 292 Installing Maintenance Utilities 293 Updating the System Applying Service Pack 294 Making Backup Copies o...

Страница 10: ...bout the System Partition Size 319 Installing Microsoft Windows Server 2003 x64 Editions 320 Creating the Windows 2003 x64 EditionsOEM Disk for ExpressBuilder 320 Windows Server 2003 x64 Editions Clea...

Страница 11: ...User Guide 10 www bull com Using Universal RAID Utility via Network 357 Easy Configuration 357 Creating Logical Drive of RAID 6 357 Appendix 8 Equipment Log 358 Hardware 359 Software 361...

Страница 12: ...or loss of life Caution Cautions indicate situations that can damage the system hard ware or software Notes give important information about the material being described Names of keyboard keys are pri...

Страница 13: ...ion of the European Community Compliance with these directives implies conformity to the following European Standards EN55022 Radio Frequency Interference EN55024 1998 A1 2001 Immunity characteristics...

Страница 14: ...harmful interference in which case the user will be required to correct the interference at his own expense Modifications to the Product CE and FCC Marking We cannot be held responsible for modificat...

Страница 15: ...not exceed 9 feet 2 7 meters Outside the U S A and Canada the plug must be rated for 250 VAC 10 amp minimum and must display an international agency approval marking The cord must be suitable for use...

Страница 16: ...an be easily damaged by static electricity To reduce risk of damage store them in protective packaging whenever they are not installed in your system Before you install or remove memory modules video...

Страница 17: ...out the ExpressBuilder DVD Chapter 2 helps you installing the server in a rack assembly and in an appropriate place making connections and starting using your server Chapter 3 shows you how to configu...

Страница 18: ...several other documents are included with your system either as electronic files on the ExpressBuilder DVD or as paper copy shipped with your server We recommend you read these additional documents as...

Страница 19: ...e server warm or cool to room temperature before using it Keep the server away from magnetic forces Keep the server dry Do not wash the system with a wet cloth or pour fluid into it Protect the server...

Страница 20: ...e and print services e mail web access web site server etc The Bull NovaScale R440 E1 server is housed and available as a rack mount system Your server conveniently installs into a standard EIA 19 inc...

Страница 21: ...User Guide 20 www bull com Server Chassis External View Figure 2 External View 1 Drive cover 2 Release button 3 Logic cover 1 2 3...

Страница 22: ...ess lamp green amber This lamp is green during access to the internal hard disks The lamp turns amber when even one of the internal hard disks fails 5 ACT lamp green This lamp lights while the server...

Страница 23: ...on off the power Pressing the switch once turns on the power The power lamp lights Pressing it again to turn off the power Pressing the switch for more than 4 seconds forcibly turns off the power 7 U...

Страница 24: ...disk lamp green amber Each hard disk lamp is green during access to the hard disk The lamp turns amber when the hard disk fails The lamp flashes switching back and forth between green and amber during...

Страница 25: ...ww bull com Rear View Non redundant power supply model Redundant power supply model Figure 6 Rear View 1 2 3 5 6 9 17 2 7 9 17 1 7 16 15 14 13 12 11 10 9 8 7 1 2 3 4 5 9 17 2 7 9 17 1 7 16 15 14 13 12...

Страница 26: ...SE TX 10BASE T interface port used to manage the server via LAN 9 Speed lamp amber This lamp indicates the transmission speed of the LAN 10 Mouse keyboard connectors Connect the mouse and keyboard to...

Страница 27: ...are going to maintain The UID LED A goes on when the UID Unit ID switch B on the front panel is pressed It goes off when the switch is pressed again Maintenance from the rear of the rack has to be car...

Страница 28: ...Model Figure 7 Internal View 1 Front panel board 2 Hard disk drive bays 3 Backplane 4 Motherboard 5 Power supply 6 Riser card module assembly 7 Chassis intrusion switch 8 DIMMs 9 Processor mounted un...

Страница 29: ...odel Figure 8 Internal View 1 Front panel board 2 Hard disk drive bays 3 Backplane 4 Motherboard 5 Power supply 6 Riser card module assembly 7 Chassis intrusion switch 8 DIMMs 9 Processor mounted unde...

Страница 30: ...nel board 2 Hard disk drive bays 3 Backplane 4 Middle plane 5 Motherboard 6 Power supply 7 RAID board 8 RAID controller is factory installed in slot 1B 9 Top cover sensor 10 DIMMs 11 Processor mounted...

Страница 31: ...ssword Clear jumper switch 8 CMOS Clear jumper switch 9 Connector for SATA2 backup device 10 Lithium battery 11 PCI Riser Card Connector slot for full height board 12 PCI Riser Card Connector slot for...

Страница 32: ...ring the ExpressScope maintains the nonvolatile Sensor Data Records SDRs from which sensor information can be retrieved The ExpressScope provides an ISA host interface to SCR sensor information so tha...

Страница 33: ...On Feature Wake On LAN The remote power on function turns on the server through a network It sends a special packet from the management computer to a remote server to turn it on if the server is off p...

Страница 34: ...ures Off line Maintenance Utility Memory dump feature using the DUMP switch High reliability Memory monitoring feature error correction error detection CPU memory degradation feature logical isolation...

Страница 35: ...User Guide 34 www bull com Easy Setup ExpressBuilder system setup utility Parameter File Creator SETUP BIOS setup utility...

Страница 36: ...are Locks via the BIOS Setup Utility The BIOS Setup Utility provides security features to prevent unauthorized or accidental access to the system Once the security measures are enabled you can access...

Страница 37: ...er the supervisor password to exit secure mode If both passwords are set you May enter the user password to enter BIOS Setup However you will not be able to change many of the options Must enter the s...

Страница 38: ...ows based applications are installed via the Windows Autorun menu Read the on line documentation Windows systems only Note Some of the above features can be performed remotely using a cross cable COM...

Страница 39: ...ove files folders to a CD R Match the root folder when you burn a CD R 6 Delete the files folders that you copied during step 3 7 Insert the CD R in the client computer on which you want to install th...

Страница 40: ...www bull com Setting Up the Server Overview This chapter describes how to select a site unpack the server install the server into a standard EIA 19 inch rack cabinet make cable connections power on o...

Страница 41: ...Warning Be sure the power service connection is through a properly grounded outlet Clean dust free and well ventilated Every side ventilating openings kept free of obstructions Away from sources of h...

Страница 42: ...prior to unpacking If the shipping boxes are damaged note the damage and if possible photograph it for reference After removing the contents of the containers keep the cartons and the packing materia...

Страница 43: ...he server is intended for installation in a Restricted Access Location mounted above a non combustible material Static Precautions An electrostatic discharge ESD can damage disk drives option boards a...

Страница 44: ...he rack Preparing before Installation The left and right slide rails are fixed with tapes at the front and side faces to prevent from falling off during transportation Peel off the tape before you ins...

Страница 45: ...sound Pull the release levers on the left and right sides of the server toward direction indicated by an arrow white in the figure and remove them from the server while unlocking it Figure 14 Removing...

Страница 46: ...in the levers or rails Installing the rail assemblies 1 Insert the square projection of the rail assembly into the angle hole on the 19 inch rack until it is locks into place The figure below shows t...

Страница 47: ...deficiency 2 Make sure that the rail assembly is surely locked to the rack Installing the Server 1 Pull out the sliding rails of the right and left rail assemblies until they lock Figure 18 Pulling O...

Страница 48: ...erver into the rack Figure 19 Pushing the Server into the Rack A Rail assembly B Inner rail at server side 4 When the server is locked on its way into the rack press the release levers blue on the rig...

Страница 49: ...server out of the rack and pushing it in several times Notes To install the server in the location adjacent to the other device pay attention to interference If the installing server disturbs the oth...

Страница 50: ...Unlock the front bezel with the security key Figure 22 Unlocking the Front Bezel A Security Key Hole 3 This step is required only when the optional cable arm is mounted Remove the cable arm from the...

Страница 51: ...server when it is pulled out from the rack Personal injuries may occur if the server falls 6 Firmly hold the server and take it out from the rack Caution Pull out the server slowly holding the bottom...

Страница 52: ...g a telephone line connector into a LAN RJ 45 port may result in personal injury and equipment damage To connect a third party peripheral device or interface cable to the server consult with your sale...

Страница 53: ...of a management PC can be connected to only serial port 2 BIOS setup required D USB device E Hub multiport repeater F Device with the serial interface G Device with the SCSI interface H Connect the p...

Страница 54: ...User Guide 53 www bull com K Keyboard L Mouse 1 100BASE T 1000BASE TX 10BASE T 2 100BASE T 1000BASE TX 10BASE T...

Страница 55: ...ia The power cord must be rated for the available AC voltage and have a current rating that is at least 125 of the current rating of the system The power cord connector that plugs into the wall outlet...

Страница 56: ...ing off the server or ejecting the floppy disk while the access lamp is lit may damage data being stored on the floppy disk After turning off the server wait at least 30 seconds before turning it on a...

Страница 57: ...Insert the attached security key into the key slot and turn the key to the front bezel side pressing it lightly The front bezel is unlocked A Unlocked B Locked Figure 27 Unlocking the Front Bezel 2 Ho...

Страница 58: ...el 1 Latch the tab at the left side of the front bezel on the server frame 1 then pull the right end of the front bezel toward the server 2 A Tab B Frame Figure 29 Installing the Front Bezel 2 Lock th...

Страница 59: ...le Power Supply make sure that the power control device is powered 3 Remove the front bezel See Removing the Front Bezel on page 56 4 Press the POWER switch on the front of the server chassis The POWE...

Страница 60: ...server management logic If you have problems powering on your server see Problem Solving on page 210 After you have powered on your server insert the ExpressBuilder DVD into the optical device drive...

Страница 61: ...need to change the settings to meet the requirements for the server As long as the above message is not displayed with an error message you don t have to launch the utility Ignore the message POST wi...

Страница 62: ...sword before installing an OS 7 The OS starts when POST completes Powering Off Your Server When the server power is on to turn the server off press the power on off switch on the front panel To power...

Страница 63: ...ull com To perform a forced power shutdown press in on the POWER on off switch located on the front panel of the server for at least 4 seconds To power on after a forced shutdown wait 30 seconds and t...

Страница 64: ...eld Use the Exit menu s Save Values selection to save the current values on all the menus To display a submenu position the cursor on a selection that has a submenu and press ENTER An arrow precedes s...

Страница 65: ...Setup Utility and provide a place for you to record any changes you make to these settings Recommended values are bold in the following tables F9 Load default configuration values for this menu F10 S...

Страница 66: ...AID Setup Utility configures the RAID system and the logical drives connected to the onboard RAID controller If your system has been factory configured the BIOS SETUP or the RAID Setup Utility do not...

Страница 67: ...ubmenus Feature Choices or Display Only Description Your Setting Type Auto None User CD ROM Select Auto if a device is attached to the IDE or serial ATA channel It is strongly recommended to keep the...

Страница 68: ...ected by the BIOS Processor 1 CPUID Display only Displays the processor CPU ID detected by the BIOS if present Disabled indicates that the CPU is defective Processor 1 L2 Cache Display only Displays t...

Страница 69: ...User Guide 68 www bull com Note The BIOS may display more options that presented here...

Страница 70: ...ory or processor error Table 7 Memory Configuration Submenu Feature Choices or Display Only Description Your Setting System Memory Display only e g 640 KB Extended Memory Display only e g 784896 KB DI...

Страница 71: ...abled Used to enable or disable an option ROM on a PCI board connected to the full height riser card PCI Slot 1C Option ROM Disabled Enabled Used to enable or disable an option ROM on a PCI board conn...

Страница 72: ...menu Feature Choices or Display Only Description Your Setting Serial Port A Disabled Enabled Auto Enables or disables the serial port A Base I O address 3F8 2F8 3E8 2E8 Set the base I O address for se...

Страница 73: ...native mode SATA AHCI Disabled Enabled Selects whether AHCI Advanced Host Controller Interface is enabled or disabled Displayed only when Enhanced is selected for SATA Controller Mode Option SATA RAID...

Страница 74: ...cess This option is available only when you log into the SETUP utility with the supervisor password Set User Password Up to 8 alphanumeric characters Press Enter to display the user password entry scr...

Страница 75: ...guration Submenu Feature Choices or Display Only Description Your Setting TPM Support Disabled Enabled Enables or disables the TPM feature Current TPM State Displays the current TPM state Change TPM S...

Страница 76: ...l 2 timer Boot Monitoring Disabled 5 Minutes 10 Minutes 15 Minutes 20 Minutes 25 Minutes 30 Minutes 35 Minutes 40 Minutes 45 Minutes 45 Minutes 50 Minutes 55 Minutes 60 Minutes Sets whether the boot m...

Страница 77: ...ervention on critical POST errors If no keyboard is connected to the system this option is ignored and the system always continues to bootup AC LINK Stays Off Last State Power On Sets the AC LINK feat...

Страница 78: ...AN2 port MAC adress Management LAN MAC Address Displays the Management LAN port MAC adress BMC Device ID Displays the BMC device ID BMC Device Revision Displays the BMC device revision BMC Frimware Re...

Страница 79: ...ify the type of remote console Remote Console Reset Disabled Enabled Enables or disables the reset function when an Escape command is sent from the remote console Table 17 Console Redirection Submenu...

Страница 80: ...automatically To specify an IP address manually set it to Disabled Web interface HTTP Disabled Enabled Set it to Enabled to use HTTP communication for the Web interface HTTP Port Number 80 Specifies t...

Страница 81: ...ure make backup copy of setting information of NEC DianaScope Note Executing Save Custom Defaults Load Custom Defaults of BIOS SETUP does not save the settings you have made in BMC LAN Configuration m...

Страница 82: ...on from a device which is not anymore used to boot Pressing Shift 1 after selecting a device enables disables the selected device 3 You can change the boot priority first to eighth of each device by u...

Страница 83: ...it Menu Choices Description Exit Saving Changes Exits after writing all modified Setup item values to NVRAM F10 key can be used for this operation Exit Discarding Changes Exits leaving NVRAM unmodifie...

Страница 84: ...han one hard disk drive HDD to be handled collectively In actual RAID can configure more than one HDDs as a single array disk group to operate the HDDs effectively This can bring higher performance th...

Страница 85: ...a disk group varies depending on the RAID level as shown in the table below Caution To use RAID 5 or RAID 6 with the Internal RAID Controller you need to install the optional RAID Upgrade Kit Note For...

Страница 86: ...guration in which the Onboard RAID Controller LSI Embedded MegaRAID or Internal RAID Controller is connected with three HDDs creating one Disk Group Two RAID5 virtual disks VD are defined in the Disk...

Страница 87: ...ID levels Caution To use RAID 5 or RAID 6 with Internal RAID Controller you need to install the optional RAID Upgrade Kit Figure 33 RAID Levels Characteristics Level Function Redundancy Characteristic...

Страница 88: ...defective the data saved in the HDD cannot be recovered RAID1 In the RAID1 level data saved in a HDD is written to another HDD without change The mode is called mirroring When data is written onto a s...

Страница 89: ...arity block Q created by different calculation method such as weighting by some factor thus it uses block level striping with two parity blocks distributed across all member disks This mode is called...

Страница 90: ...Onboard RAID Controller LSI Embedded MegaRAID of 3 5 inch disk model Installing the Hard Disk Drives Install two or more SAS hard disk drives to your server See Installing and Removing a Hard Disk Dri...

Страница 91: ...the position of the RAID Configuration jumper on the motherboard as shown below Figure 38 RAID Configuration Jumper on Motherboard 5 Remove the jumper from position 2 3 on jumper block 6 Reinstall the...

Страница 92: ...rl M on POST screen Figure 39 LSI Software RAID Configuration Utility TOP Menu Management Menu To quit the utility press Esc in the TOP menu When a confirmation message appears select Yes When the abo...

Страница 93: ...virtual drive when multiple virtual drives exist Initialize Initialize virtual drive Check Consistency Check virtual drive redundancy View Update Parameters Display virtual drive information RAID Dis...

Страница 94: ...d disk drive capacity Product ID Hard disk drive model Revision No Hard disk drive revision Rebuild Perform rebuilding Check Consistency Perform virtual drive redundancy check Run LSI Software RAID Co...

Страница 95: ...n information to an existing Configuration select View add Configuration You cannot create a Spanning of RAID1 or set the virtual drive capacity on the Easy Configuration menu Use the New Configuratio...

Страница 96: ...The display for the selected hard disk drive changes from READY to ONLINE 4 Press F10 to set Select Configurable Array s 5 Press Space SPAN 1 is set 6 Press F10 to create a virtual drive The Virtual...

Страница 97: ...good performance however cache data may be lost at an unexpected power failure Write back Off reduces performance by approximately 50 5 Span Sets the Span When performing SPAN create two or more sets...

Страница 98: ...u screen 13 When the Virtual Drives screen appears move the cursor to the virtual drive to be initialized and press Space The virtual drive is selected 14 After selecting virtual drive press F10 to st...

Страница 99: ...or onto the hard disk drive displaying FAIL and then press Space to select it Multiple hard disk drives can be selected simultaneous rebuilding 5 The FAIL indication for the hard disk drive selected s...

Страница 100: ...y Setting Hot Spare 1 Install a hard disk drive to be used as hot spare and then turn on the server 2 Run the LSI Software Raid Configuration Utility 3 Select Objects Physical Drive from the TOP menu...

Страница 101: ...isk drive indication is changed to HOTSP 7 Press Esc to return to the TOP menu and exit the LSI Software Raid Configuration Utility Figure 44 Physical Drives Selection menu Caution Select Objects Phys...

Страница 102: ...press F10 to start the Consistency Check 5 When prompted to do so press Yes The Consistency Check starts When the progress bar in the Check Consistency Progress screen indicates 100 the Consistency Ch...

Страница 103: ...ail if you select the Configuration information on the RAID Controller In this case execute Clear Configuration to create Configuration again LSI Software Raid Configuration Utility cannot delete each...

Страница 104: ...er starting from 1 You can see the RAID Controller number using Number in the RAID Controller properties on the RAID Viewer or using RAID Controller X in the RAID Controller properties on the raidcmd...

Страница 105: ...rt of Objects PHYSICAL DRIVE SELECTION MENU DG X in the Objects menu The Universal RAID Utility identifies Physical Devices starting from 1 and using an ID You can see the number and ID of a Physical...

Страница 106: ...ize Priority whereas the Universal RAID Utility cannot The Universal RAID Utility can set an Initialization Priority but it can t set it to the LSI Embedded MegaRAID Therefore the Universal RAID Utili...

Страница 107: ...Internal RAID Controller can automatically start the Rebuild The Auto Rebuild can be of two types as follows Standby Rebuild Automatic Rebuild by using hot spares In the configuration including hot sp...

Страница 108: ...n firmware To change the Patrol Read settings use the Universal RAID Utility If the system is restarted while running Patrol Read Patrol Read resumes from the point where it was stopped Consistency Ch...

Страница 109: ...s already been executed and completed normally before executing a Background Initialize for RAID5 only Yes is specified for Disable BGI in VD Definition The Virtual disk is in degraded or offline stat...

Страница 110: ...tion with addition Before execution After execution Description RAID level Number of HDDs RAID level Number of HDDs RAID0 x RAID0 x Capacity increased equivalent to HDDs RAID0 1 RAID1 2 Capacity remai...

Страница 111: ...t shutdown or reboot the server If the server is shutdown by an unforeseen accident such as power interruption power on again as soon as pos sible The Reconstruction restarts automatically In some con...

Страница 112: ...OS in VD under the Internal RAID Controller create a VD dedicated to the OS installation WebBIOS cannot be handled via the remote console functions of NEC DianaScope The physical drive numbers shown i...

Страница 113: ...in the Universal RAID Utility Using WebBIOS Starting WebBIOS 1 Power on the server and press Esc when a full screen logo is displayed 2 Press Ctrl H on the POST screen to start WebBIOS LSI MegaRAID S...

Страница 114: ...the system proceeds without displaying the WebBIOS main menu shown on the next page reboot the system and press Ctrl H on the POST screen Main Menu The screen shown below is the Adapter Selection scr...

Страница 115: ...nu Screen Caution X X X shown in Physical Drives box represents Connector number Enclosure number Slot number With this server the Connector number is not supported thus it is always indicated as The...

Страница 116: ...When you click Adapter Properties on WebBIOS Top Menu the configuration information is displayed Figure 49 Configuration Information Screen Click Next to see the detailed settings of this controller F...

Страница 117: ...User Guide 116 www bull com The detailed settings continues on the next page Click Next to view more information Figure 51 Detailed Controller Settings Screen 2...

Страница 118: ...tted BGI Rate 30 Recommended value 30 Permitted CC Rate 30 Recommended value 30 Permitted Reconstruction Rate 30 Recommended value 30 Permitted Adapter BIOS Enabled Disabled Prohibited Coercion Mode N...

Страница 119: ...wn below Figure 52 Battery Status Screen Warning You cannot change the values for the Auto Learn Period Next Learn Time and Learn Delay Interval Notes The Status field shows Charging when the battery...

Страница 120: ...ontains another configuration information the Foreign Configuration screen shown below appears To use the HDD as new one click Clear to clear the configuration information in HDD Figure 53 Foreign Con...

Страница 121: ...n the WebBIOS Top Menu the screen for operating the VD that has already been configured is displayed Figure 54 Virtual Disks Operation Screen Caution If no virtual disk exists the upper right column o...

Страница 122: ...l Disks on the WebBIOS Top Menu the screen for operating the physical drive HDD appears Figure 55 Physical Drive Operation Screen Caution If no hard disk drive exists the upper right column of the scr...

Страница 123: ...eck 2 Click the checkbox for Properties 3 Click Go Figure 56 Physical Drives Properties Screen 1 The Properties screen shown below appears Figure 57 Physical Drives Properties Screen 2 Configuration W...

Страница 124: ...displays the virtual disk in the DG Events The Events screen is used to confirm the system events Caution The Internal RAID Controller does not support the Events fea ture Exit When you click Exit on...

Страница 125: ...hown below is displayed Select the relevant operation and click Next at lower right of the screen Figure 60 Configuration Wizard Screen 1 Clear Configuration Allows you to clear existing configuration...

Страница 126: ...een 2 Caution The Internal RAID Controller only supports Custom Configura tion Custom Configuration Allows you to define all aspects of the configuration RAID level size and others Auto Configuration...

Страница 127: ...disk group DG Figure 62 Configuration Wizard Screen 3 1 To add physical drives HDD to a Disk Group hold Ctrl while selecting physical drives HDDs in DG Figure 63 Configuration Wizard Screen 4 2 Once t...

Страница 128: ...isk Groups frame To define the new DG click Accept DG Figure 65 Configuration Wizard Screen 6 4 Once the DG has been defined click Next Figure 66 Configuration Wizard Screen 7 5 Then the Span Definiti...

Страница 129: ...lick Next Caution To configure RAID0 1 5 or 6 perform Span Definition to a single DG only If you need to perform Span Definition to several DGs define VD for the first DG then select the next DG to de...

Страница 130: ...User Guide 129 www bull com LD Possible RAID Levels column the available RAID levels and maximum size for the VD are displayed Figure 69 Configuration Wizard Screen 10...

Страница 131: ...fined click Next Caution The value shown in Select Size indicates the maximum size allowed for RAID1 or RAID6 You need to specify the maximum size for RAID0 or RAID5 according to Next LD Possible RAID...

Страница 132: ...rrectly and click Accept at the lower right of the screen 8 The confirmation message Save this Configuration appears Click Yes to save the configuration 9 The confirmation message All data on the new...

Страница 133: ...you have created is displayed in the lower right frame of the screen Figure 71 WebBIOS Top menu Configuring a SPAN The following explains the procedure to configure a RAID10 spanning of RAID1 with fou...

Страница 134: ...isk Group hold Ctrl while selecting the HDDs in the DG In the example two DGs will be configured and spanned Figure 73 Span Configuration Wizard 2 3 Upon completion of selection click Add to Array at...

Страница 135: ...res Once the DGs have been defined click Next at the lower right of the screen Figure 75 Span Configuration Wizard 4 5 Configure a RAID10 spanning of RAID1 using the two DGs that have been created in...

Страница 136: ...Space frame then click Add to SPAN The DG is defined in the Span field to the right Figure 77 Span Configuration Wizard 6 7 Select DG1 and click Add to SPAN When the two DGs are defined in the Span fi...

Страница 137: ...VD Definition screen is displayed Enter the necessary parameters and click Accept Figure 79 Span Configuration Wizard 8 9 Make sure that both the DG0 and DG1 are defined as VD 0 then click Next Figur...

Страница 138: ...s Click Yes to save the configuration 12 The confirmation message All data on the new Virtual Disks will be lost Want to Initialize appears Normally select Yes 13 The Virtual Disks operation screen is...

Страница 139: ...0 RAID 1 RAID 5 RAID 6 RAID 00 RAID 10 RAID 50 RAID60 RAID 00 RAID 10 RAID 50 and RAID 60 are not supported Strip Size 8 KB 16 KB 32 KB 64 KB 128 KB 256 KB 512 KB 1024 KB Recommended value 64KB Access...

Страница 140: ...ting However if the battery is being charged or failed the controller operates in WThru write through mode automatically Thus this mode can provide higher data secu rity Constant write back mode This...

Страница 141: ...e Check Consistency from the upper right frame of the Virtual Disks screen 4 Click the checkmark column for the Check Consistency from the lower right frame of the Virtual Disks screen 5 Make sure tha...

Страница 142: ...pro cess at a slower rate Manual Rebuild The procedure below is based on the following assumption One of the HDDs failed in a RAID5 virtual disk configured with three HDDs Replace the failed HDD with...

Страница 143: ...that the PD physical drive installed in slot number 2 was removed Figure 85 WebBIOS Top Menu 2 Select 1 2 newly connected HDD in Physical Drives The Physical Drive properties screen is displayed 3 Se...

Страница 144: ...left of the screen to go back to WebBIOS Top Menu Figure 87 Rebuild Progress Screen Caution Click Home while a background task such as Consistency Check Rebuild or Reconstruction is being executed Wh...

Страница 145: ...icated as UNCONF GOOD in the right frame of the Top Menu Figure 88 Top Menu Screen 2 Select 1 3 newly connected HDD in Physical Drives 3 The Physical Drive properties are displayed 4 Select Make Globa...

Страница 146: ...reen Do not check Enclosure Affinity which defines the hot spare to a specific enclosure This setting is not supported in the system The status for the newly connected HDD changes to HOTSPARE 5 Click...

Страница 147: ...HDD to a RAID5 virtual disk configured with three HDDs to make a RAID5 virtual disk configured with four HDDs 1 Start WebBIOS Make sure that the status for the added HDD is indicated as UNCONF GOOD in...

Страница 148: ...The items required for the reconstruction are displayed Figure 93 Reconstruction Settings Screen Information about HDDs in the disk group in which a VD is defined Migration only Allows to change a RAI...

Страница 149: ...Reconstruction is being executed When the progress indication is displayed the background task may process at a slow rate WebBIOS and Universal RAID Utility You can use the Universal RAID Utility for...

Страница 150: ...an also see the Logical Drive number managed by WebBIOS where ID in the property of Logical Drive by Universal RAID Utility RAID system WebBIOS identifies the RAID system starting from 0 You can see t...

Страница 151: ...iority and the Consistency Check Priority of the RAID Controller using a percentage whereas the Universal RAID Utility uses three levels High Middle Low Table 31 Priority and Value Settings Item WebBI...

Страница 152: ...Therefore the Universal RAID Utility doesn t display the Initialization Priority in the RAID Controller properties Changing the Ini tialization Priority by raidcmd command will also fail Low 10 Patrol...

Страница 153: ...lear the CMOS data in the server Caution Clearing the CMOS data resumes the factory set configura tion data After clearing CMOS you must run the BIOS SETUP utility and execute the following menus to r...

Страница 154: ...page 156 for details Do not disassemble repair or alter the server Do not remove the lithium battery Do not connect the ground line to a gas pipe Caution Observe the following instructions to use the...

Страница 155: ...n Do not install the server on a rack with leaving covers removed Do not pinch your finger with mechanical components Note high temperature Do not pull out a device from the rack if the rack is unstab...

Страница 156: ...Password cleared or CMOS cleared message is displayed about 5 seconds 7 Power off the server and disconnect the power cord 8 Re install the jumper block to the default position 9 Reinstall the cover...

Страница 157: ...of the chassis Failure to disconnect power before opening your server can result in personal injury and equipment damage Caution Operating your system with the upper access panel removed can damage y...

Страница 158: ...nd other components You can provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground when handling system components Electronic devices can be easily damaged by stat...

Страница 159: ...er pertinent information specific to your server You will need this information when configuring your server See Appendix 8 Equipment Log on page 358 Tools Recommended for Upgrading Your Server Depend...

Страница 160: ...t Bezel on page 56 A Unlocked B Locked Figure 95 Unlocking and removing the Front Bezel 4 Power off the server then press the POWER switch on the front panel of the server The POWER lamp goes out 5 Un...

Страница 161: ...Unlock Button A Unlock button 9 Push the right and left release levers blue forward or rearward to unlock and slowly pull out the server from the rack Figure 97 Pushing the Release Levers Caution Do n...

Страница 162: ...nboard RAID Controller LSI Embedded MegaRAID LSILogic MegaRAID SAS 8480E Controller Disk Array Controller SAS SATA HW RAID0 1 Disk Array Controller SAS SATA HW RAID5 6 Up to three hard disk drives mou...

Страница 163: ...a failure of the server as well as the hard disk Purchase hard disks of the following models 36 3 GB 15000 rpm SAS 73 2 GB 15000 rpm SAS 146 5 GB 15000 rpm SAS 300 GB 15000 rpm SAS Figure 99 SAS hard...

Страница 164: ...representative Installing a third party hard disk may cause a failure of the server as well as the hard disk Purchase hard disks of the following models 36 3 GB 10000 rpm SAS 73 2 GB 10000 rpm SAS 14...

Страница 165: ...the hard disk drive if your server is running 1 Read section Preparing Your Server for Upgrade on page 159 2 Unlock of the front bezel with the security key and remove the front bezel 3 Locate the sl...

Страница 166: ...isert it into the chassis Caution Do not push on the handle before it begins to close by itself Carefully hold the hard disk drive with both hands Do not press the POWER switch during the installatio...

Страница 167: ...ity When you install an additional hard disk drive the boot priority stored in the BIOS is cleared 9 Replace the front bezel you removed in step 2 There are tabs on the left side of the front bezel En...

Страница 168: ...5 Unlocking the Hard Disk Drive 3 5 in drive Figure 106 Unlocking the hard disk drive 2 5 inch model Caution Do not press the POWER switch during the installation or removal of the hard disk drive if...

Страница 169: ...ling out the hard disk drive 2 5 inch model 5 When using the server without replacing the hard disk drive remove the hard disk drive from the disk tray remove the four screws and replace the empty tra...

Страница 170: ...d fails the DISK lamp lights in amber Remove and install the hard disk again to restart auto rebuild If the RAID system management utility is installed it may display or act as follows Displays Rebuil...

Страница 171: ...ation of the system in the unlikely event one of the power supplies fails Installing a Power Supply Unit 1 Read section Preparing Your Server for Upgrade on page 159 Caution Turn off the power Failure...

Страница 172: ...unit in the server Figure 110 Inserting the Power Unit in the Server Caution Do not touch the terminals A of the power supply unit A Contact terminals 6 Grasp the handle and firmly push the power supp...

Страница 173: ...necting the Power Cords A Power supply unit 1 Option B Power supply unit 2 Standard 8 Power on the server The AC POWER lamps go on Figure 113 AC Power lamps A AC Power LED 9 Confirm by the STATUS lamp...

Страница 174: ...h power supply unit The lamp of the failing power supply unit is amber 2 Shutdown the server 3 To turn off the power press the POWER switch 4 Disconnect the power cord from the failing power supply un...

Страница 175: ...unit See Installing a Power Supply Unit on page 170 9 Check that the power supply unit is installed correctly Note If one of the two power supply units of the server is replaced while the power is on...

Страница 176: ...parate parts the front part drive cover that has be removed to install or remove a 5 25 inch optical device the rear part logic cover that has to be removed to install or remove DIMMs or PCI boards Th...

Страница 177: ...g Your Server for Upgrade on page 159 2 Pull out the server from the rack 3 Slide the drive cover toward the rear of the server while pressing the lock button on the cover 4 Lift off the drive cover f...

Страница 178: ...Guide 177 www bull com 2 Slide the drive cover toward the rear of the server until you hear a click The drive cover is locked 3 Check the release button for normal state Figure 117 Chassis release bu...

Страница 179: ...ard or reconnecting an internal cable Removing the Logic Cover 1 Read section Preparing Your Server for Upgrade on page 159 2 Pull out the server from the rack 3 Remove the captive thumbscrew at the r...

Страница 180: ...of the server and secure the cover with the captive thumbscrew Figure 119 Installing the Logic Cover 2 Check that the tab of the cover is securely inserted into the slot in the server frame Note If th...

Страница 181: ...tricity Handle the DIMM after making your body contact with a metallic frame section of the server to discharge the static electricity on your body Do not make bare hands contact with terminals and co...

Страница 182: ...y RAS Features on page 183 to configure the memory mirrorins and online sare memory fea tures Installing DIMMs Caution The server supports DIMMs of only the low profile type 30 mm 1 2 inches in height...

Страница 183: ...ocket the lever is automatically closed Figure 121 Inserting the module Note Make sure of the orientation of the DIMM Position the DIMM so that a notch in the bottom edge of the DIMM aligns with the k...

Страница 184: ...led To remove a DIMM module 1 Read section Preparing Your Server for Upgrade on page 159 2 Pull out the server from the rack 3 Open the logic cover See Removing the Logic Cover on page 178 4 Open the...

Страница 185: ...re 122 Memory Branches A Motherboard B Memory Controller C Memory Branch 1 D Memory Branch 2 The memory mirroring and online spare memory features keep memory redundancy between memory branches and wi...

Страница 186: ...under the following conditions Install memory modules on four memory sockets configuring a mirror set All the installed memory modules should have the same capacity Run SETUP change the parameters app...

Страница 187: ...r the parameter values you saved in step 1 Note Executing Load Setup Defaults restores the default values for all Setup parameters You need to specify those parameters again The table below lists exam...

Страница 188: ...Branch 1 E In Operation F Standbys Note The operating system recognizes the memory devices as those with capacities less than the actual physical capacities The recognized capacities vary depending on...

Страница 189: ...paring to another memory branch The table below lists examples of DIMM installation patterns enabling the online spare memory feature to be used While the following patterns are provided for memory br...

Страница 190: ...e CPU pins Do not place the CPU directly on the desk See Static Precautions on page 157 for details about the static electricity Do not operate the server until confirming that the addition ally insta...

Страница 191: ...www bull com Note If the different revision of the processor is installed in the multiprocessor system Windows logs the following informa tion every startup If this message is logged it is no problem...

Страница 192: ...nd the logic cover Removing the Logic Cover on page 178 4 Remove the processor air duct from the chassis Figure 126 Removing the Processor Air Duct 5 Locate the CPU socket which you are going to insta...

Страница 193: ...ate Figure 129 Lifting the Load Plate Caution Do not touch the socket contacts 9 Remove the processor from the protective cover Caution Hold the processor only at the edges being careful not to touch...

Страница 194: ...n Make sure fingers align to the socket cutouts Figure 130 Holding the processor A Pin Marker B Notches C Key 11 Align notches with the socket 12 Lower the processor straight down without tilting or s...

Страница 195: ...care of the direction of the heat sink see figure below 15 Make sure that the heat sink is level Notes If the heat sink is not level remove it and then install it again The following probably causes t...

Страница 196: ...cables A USB cables B Processor duct C Heatsink 17 Install the processor air duct Figure 134 Installing the CPU Duct Note Place the internal USB cable inside the processor duct see figure above Check...

Страница 197: ...Configuration Data on the Advanced menu to Yes This setting is required to change the hardware configuration data See BIOS Setup Utility on page 63 for details 21 Verify that POST displays no error me...

Страница 198: ...eat sink with it adhering to the CPU may cause the CPU and or socket to be defected Figure 136 Removing the Heat Sink Do the following procedure if a CPU is removed or replaced 1 Start BIOS Setup to s...

Страница 199: ...m your body before handling the PCI board Do not touch the PCI board terminals or on board parts by a bare hand or place the PCI board directly on the desk See Static Precautions on page 157 Some rest...

Страница 200: ...the slot location of PCI device by PCI bus num ber device number and function number shown in the table below Set Disabled for the optional ROM of a LAN device not to be booted by using the BIOS SETUP...

Страница 201: ...I boards Before installing a PCI board check the type of the PCI board When installing a PCI board check that the card connector matches the connector of the riser card To install a PCI board on the r...

Страница 202: ...the extension slot cover A Low Profile type B Full height type 6 Install the PCI board on the riser card Align the PCI board terminal section with the riser card slot and firmly push the PCI board un...

Страница 203: ...board or riser card Doing so may damage the card Note Check that the end of the PCI board bracket is inserted in the frame slot of the riser card Some PCI boards have a terminal section that extends o...

Страница 204: ...al section The riser card is now fully seated in the slot Pay attention not to damage the components on the mother board with the riser card when inserting it into the slot Figure 142 Inserting the Ri...

Страница 205: ...the array has your valuable data stored make sure to make a backup copy of the data before installing the RAID controller board and configuring the array At least two hard disk drives are required to...

Страница 206: ...the hard disk drive interface cable on the motherboard At the factory the interface cable is connected to the Mini SAS connector on the motherboard Refer to the manual coming with optional RAID Contro...

Страница 207: ...quipped with LED cable connector To use internal hard disk drives in a RAID System by con necting the RAID Controller to the full height riser card first connect the cable then connect the riser card...

Страница 208: ...disks depends on the configuration of RAID Redundant Arrays of Inexpensive Independent Disks Select set a RAID level RAID0 RAID1 RAID5 or RAID6 When installing an operating system in an internal hard...

Страница 209: ...n unit is provided without hard disk drives The hard disk drives must be purchased separately An optional cable may be required to connect with a disk expansion unit Refer to the manual provided with...

Страница 210: ...tery To replace the battery on the motherboard 1 Turn off and unplug the server and any external options connected to the server 2 Remove the top cover See Removing and Replacing the Top Cover on page...

Страница 211: ...nd an AC outlet Before doing the proce dures in this manual make sure that your system is powered off and unplug the AC power cords from the back of the chassis Not disconnecting power before opening...

Страница 212: ...re that no processing is in progress Hard reset Press the power switch A at the front of the server See Forcing a Power Shutdown on page 61 Caution If the remote power on function is used cycle the po...

Страница 213: ...he power indicator does not light up but the system seems to be operating normally the indicator may need replacement 4 Monitor the power on self test POST execution Each time you turn on the system t...

Страница 214: ...ches and jumpers on the system board correct if they have been changed from their original default settings Are all jumper and switch settings on optional add on cards and peripheral devices set corre...

Страница 215: ...einstall the software on the hard disk and try again If problems appear intermittently there may be a loose cable dirt in the keyboard if keyboard input is incorrect or other random component failures...

Страница 216: ...Does the system meet the minimum hardware requirements for the software Refer to the software documentation Is the software an authorised copy Unauthorised copies often do not work Obtain an authoris...

Страница 217: ...k your monitor s documentation Characters do not appear on screen Make sure the monitor is plugged in and turned on Are the brightness and contrast controls properly adjusted Make sure that the video...

Страница 218: ...n completion of POST See the table for POST error codes for details Figure 145 Virtual LCD Screen A Message sent from BIOS B Message sent from BMC C Virtual LCD D Status indicators Figure 146 BIOS Mes...

Страница 219: ...Prepare to Boot POST completed normally This is not an error Figure 147 BMC Messages Lower Line On screen message Description 240VA Power Down Power supply failure occurred BB 1 5v Alm XX Voltage ala...

Страница 220: ...emperature fetal Proc2 VccpAlm XX Processor 1 IERR IERR occurred on processor 1 or 2 Processor 2 IERR SMI timeout SMI timeout occurred Sys Fan 1 Alarm FAN 1 alarm occurred Sys Fan 2 Alarm FAN 2 alarm...

Страница 221: ...on the front of the server to turn on the power the POWER SLEEP lamp lights Fail to power off the server Is the power switch enabled Restart the server and start the BIOS setup utility Is the server...

Страница 222: ...ait for a while Did you perform any keyboard or mouse operation immediately after you started the server If you perform any keyboard or mouse operation immediately after start up POST may accidentally...

Страница 223: ...of the server first and connect it properly Is the BIOS configuration correct The keyboard and mouse may have been disabled with the BIOS SETUP utility of the server Check the settings with the BIOS...

Страница 224: ...is not authorized by Bull is not guaranteed Is the cable connection changed Are SCSI devices properly configured When the server has external SCSI devices connected devices settings includ ing SCSI ID...

Страница 225: ...ID 22 Description Primary Adapter does not sense any Probes Intel R PRO 1000 Possible reason partitioned Team Above mentioned event log will appear when the system starts There is no problem in LAN dr...

Страница 226: ...red with a RAID system does not operate properly or if an utility does not operate correctly Fail to install the OS s the RAID controller configured Provide proper configuration for the RAID controlle...

Страница 227: ...D Configuration Utility Menus to check Top menu Objects Adapter Auto Rebuild Auto Rebuild cannot be specified in WebBIOS A hard disk drive fails Contact your service representative Cannot enter standb...

Страница 228: ...or Event ID 1001 Description The IPMI device driver attempted to determine if the system supported an IPMI BMC device The driver attempted to detect the presence of the IPMI BMC by searching the SMBIO...

Страница 229: ...em does not restart automatically when a stop error occurs though the system is adjusted to automatically restarting When the system does not restart automatically restart it manually The system resta...

Страница 230: ...click the Services to specify whether the Telnet Service is registered Once the installation of Telnet Service is finished you can reset the computer name to 15 characters or more Power ON OFF Wake On...

Страница 231: ...he system partition created by size about 8MB smaller than specified size It is not a problem in operating the system Following message appeared when you tried to install Express Setup to the hard dis...

Страница 232: ...following information may appear in browser To help protect your security Internet Explorer has restricted this file from showing active content that could access your computer Click here for options...

Страница 233: ...environment correct The menu items are grayed out when the logon user does not have the authority of the Administrator or the system does not meet the requirements to install the application Login wit...

Страница 234: ...Guide 233 www bull com Collecting Dr Watson Diagnostic Information Dr Watson collects diagnostic information related to application errors The location to save the information can be specified as you...

Страница 235: ...server to shut down This forced shutdown however is not available if Enable is selected for Power Switch Inhibit on the Security menu of the BIOS setup utility SETUP because this setting disables POWE...

Страница 236: ...tarts according to the following procedure 1 Turn on first the peripheral devices and then the server 2 Insert the ExpressBuilder DVD supplied with your server into the optical disc drive of your serv...

Страница 237: ...sing the remote console Maintenance Tools Redirection mode is selected Caution The initial selection of the menu is Japanese Japanese starts automatically if no other choice is made dur ing the follow...

Страница 238: ...that describes the operation of the utility but we recommend you do not attempt to use the utility by yourself Contact your service representative and follow their instructions See the on line help fo...

Страница 239: ...he system from the floppy disk and the various BIOS and firmware programs are updated Caution Do not turn off the server while the update program is running If this update process is interrupted the s...

Страница 240: ...o methods to start the server Run the Maintenance Tools from the management PC via the LAN Run the Maintenance Tools from the management PC via a direct connection COM2 Caution Do not change the boot...

Страница 241: ...response to a keyboard instruction simultaneous key entry of Ctrl Alt Delete Immediately after the system is rebooted in response to an OS instruction During hardware initialization following restart...

Страница 242: ...led at offset 0232 Extended RAM Failed at address line 0250 System battery is dead Replace and run SETUP Contact your service representative to replace the battery After restarting the computer start...

Страница 243: ...rred 0B3A FAN11 Alarm occurred 0B3B FAN12 Alarm occurred 0B3C FAN13 Alarm occurred 0B3D FAN14 Alarm occurred 0B3E FAN15 Alarm occurred 0B42 Resource conflict Contact your service representative 0B43 W...

Страница 244: ...contact your service representative 0B94 IPMB signal lines do not respond This is not a fatal error Turn off the power once and then on again to restart the server If the error cannot be corrected con...

Страница 245: ...ne Expansion ROM not initialized PCI Mass Storage Controller in slot n n slot number Disable initialization of the optional device expansion ROM by using the BIOS SETUP utility see BIOS Setup Utility...

Страница 246: ...rmally 3 Ask your service representative to replace the failed DIMM or motherboard 1 3 1 3 Keyboard controller error 1 Check if the keyboard is properly connected 2 Replace the motherboard 1 3 3 1 No...

Страница 247: ...ver 2003 running the command blinks the POWER lamp in green and place the server in the power saving mode Press the POWER switch to turn out the POWER lamp and place the server back in the normal mode...

Страница 248: ...green The server is operating with the memory CPU or power supply unit in degraded state An uncorrectable memory error has often occurred Check the AC power lamp indication on the rear panel of the se...

Страница 249: ...the servers on a rack Refer to Identification of Servers UID Switch on page 26 for more information on the UID switch Disk Access Lamp The disk access lamp of the optical device drive is on while the...

Страница 250: ...hat the hard disk is accessed On amber The lamp indicates a failure of a hard disk mounted in a RAID configuration Note Even if one two in RAID6 of the hard disks fails in the logical drive RAID1 RAID...

Страница 251: ...the rebuild processing finishes It turns amber when the rebuild processing fails Caution If the server is turned off during rebuild processing the process ing is stopped Restart the server mount the...

Страница 252: ...whether each of the network ports normally equipped with the server is operated through the 1000BASE T 100BASE TX or 10BASE T network interface If the lamp is lit orange the network port is operated...

Страница 253: ...your service representative to replace the power supply unit Figure 154 AC Power LED A Power supply slot option B Power supply slot standard 1 AC inlet 2 AC Power LED Note If one power supply unit fai...

Страница 254: ...TA2 Serial ATA 2 2250 GB 750 GB x 3 maximum SAS Serial Attached SCSI 900 GB 300 GB x 3 maximum with optional RAID controller installed Hard Disk Bay Slots 6 2 5 inch 3 3 5 inch RAID controller SAS Ser...

Страница 255: ...e TX 10Base T 1 management port Power supply 100 to 120 VAC 10 200 to 240 VAC 10 50 60 Hz 1 Hz Redundant Power Supply Supported option None Redundant Fans Supported standard None Weight Max 16 kg max...

Страница 256: ...Device Controller IRQ Peripheral Device Controller 0 System timer 12 Mouse 1 Keyboard 13 Numeric processor 2 14 Primary IDE 3 COM2 serial port PCI 15 Secondary IDE 4 COM 1 serial port PCI 16 USB 5 PCI...

Страница 257: ...ID system configuration data if your system is in the RAID system configuration When your hard disks have been auto rebuilt due to a failure it is recommended to make a backup copy of the configuratio...

Страница 258: ...e server with the cloth prepared in Step 4 6 Soak a soft cloth in water squeeze it firmly wipe the server with it once again 7 Wipe the server with a dry cloth 8 Wipe off dust from the fan exhaust ope...

Страница 259: ...eaning material that will generate an electrostatics To clean the interior of the server 1 Turn off the server and unplug all power cables 2 Remove the logic cover and the drive cover 3 Use a small br...

Страница 260: ...rm water and squeeze it firmly 6 Rub off stains on the mouse ball Softly wipe the mouse ball with the cloth prepared in Step 5 7 Wipe the mouse ball with a dry soft cloth 8 Wipe three small rollers in...

Страница 261: ...e 5 Push on the tray front to close the tray To Clean an Optical Disc Wipe the signal side of the disc with a dry soft cloth Caution Wipe disks from the center to the outside Use only a specific clean...

Страница 262: ...o diagnose the system Test Items The following items are tested in system diagnostics Memory CPU cache memory Hard disk used as a system Caution When executing the System Diagnostics make sure to remo...

Страница 263: ...ce Tools Redirection mode when using a remote console 5 Select English 6 Select Tests and Diagnostics 7 Select End User Mode and the system diagnostics starts The diagnostics will be completed in appr...

Страница 264: ...y disk To save the log information to a floppy disk insert a formatted floppy disk to a floppy disk drive and select Save F Option gives access to the different option menus Reboot restarts the server...

Страница 265: ...Microsoft Windows Server 2003 Standard Edition Microsoft Windows Server 2003 Enterprise Edition Microsoft Windows Server 2003 R2 Standard Edition Microsoft Windows Server2003 R2 Enterprise Edition To...

Страница 266: ...ess Setup erases all data on the hard disk drive You can also use the Parameters File during Express Setup in order to save or backup the installation parameters If you want to set up the server using...

Страница 267: ...to use the drivers located on the OEM Disk for Mass Storage Device that ships with optional boards a parameters file is mandatory You can create a parameters file in advance using the Parameter File...

Страница 268: ...osoft Windows Server 2003 without Express Setup on page 296 Notes on the Windows Installation Check the following before starting the Express Setup About the Windows family This computer supports the...

Страница 269: ...are Components When you install Windows Server 2003 Express Setup requires several preparations if this computer uses the following hardware components Installing on the Mirrored Volume If you want to...

Страница 270: ...ile Size Application Size Size necessary to install the system 3500MB Windows Server 2003 R2 3500MB Windows Server 2003 with Service Pack1 3500MB Windows Server 2003 R2 with Service Pack2 5300MB Windo...

Страница 271: ...ded size onto multiple disks as written below if it cannot be reserved in one disk 1 Set the Size required for installation Paging file size 2 Set the debugging information equivalent to the dump file...

Страница 272: ...and then turn on the server 2 Insert the ExpressBuilder DVD into the Optical Disc drive of the server 3 Press the RESET switch or press Ctrl Alt and Delete to reboot from the ExpressBuilder You may al...

Страница 273: ...User Guide 272 www bull com 4 Select Perform the Express setup from the Top Menu and click Next 5 The Load parameters step is displayed Do not load parameters...

Страница 274: ...ected select this item Load parameters a Insert the floppy disk containing the parameters file b Select Load parameters and enter the file path of the parameters file into the text box c Click Next 6...

Страница 275: ...the virtual disk settings The Enter RAID settings step is displayed Confirm the parameters modify if necessary and then click Next Notes You can use only physical devices that have an identical model...

Страница 276: ...If you select Create a new partition at Windows system drive settings the contents of the hard disk will be all deleted If Use existing partitions is selected ExpressBuilder installs the Operating Sy...

Страница 277: ...information time zone and client license mode The Enter basic parameters step is displayed Confirm the parameters modify if necessary and click Next Notes Even if you do not input a value into Adminis...

Страница 278: ...ings The Enter Network Protocol step is displayed Confirm the parameters modify if necessary and click Next 11 Enter the domain or workgroup name to be used The Enter domain and account step is displa...

Страница 279: ...o install The Select Windows component step is displayed Confirm the parameters modify if necessary and click Next 13 Select the applications to install The Setting applications step is displayed Conf...

Страница 280: ...s The Save parameters step is displayed If you want to save the parameters set the free formatted floppy disk Select Save parameters enter the file path of the parameters files into the text box and c...

Страница 281: ...f you proceed with the setup by using the setup parameters file remove the floppy disk from the floppy disk drive Insert the Windows Server 2003 CD ROM into the Optical Disc drive The Agree Software L...

Страница 282: ...your system you do not have to apply the Service pack 2 again Windows Server 2003 and the specified application will be installed automatically Install and configure the device drivers 20 If you insta...

Страница 283: ...as one team provides the server with a tolerant environment and enhances throughput between the switches PROSet is necessary to use these features Follow the procedure below to install PROSet 1 Inser...

Страница 284: ...dialog box appears Right click Local Area Connection and click Properties from the pop up menu 2 Click Configure The properties dialog box for the network adapter appears 3 Click Advanced and specify...

Страница 285: ...tallation of the Optional Network Board Driver 1 Start the Device Manager 2 Click Network adapters and double click Network Adapter Name The Network Adapter Name Properties appears Note Intel R PRO 10...

Страница 286: ...sure to remove the adapter teaming before the exchange and recreate the adapter team once the exchange is completed If you want to use the AFT ALB feature follow the procedure below to setup 1 The Int...

Страница 287: ...manually If you want to use an optional Graphics Accelerator Driver board follow the document attached to the board to install the driver 1 Insert the ExpressBuilder into the optical disc drive Close...

Страница 288: ...as Other device 3 Click Update Driver 4 When the Update Device Driver Wizard appears select No not this time and click Next 5 Select Install from a list or specific location Advanced and click Next 6...

Страница 289: ...ion of the 4GB RAM tuning feature and the Physical Address Extension switch Below is the example on how to add PAE switch to Boot ini file 1 Click Start point to Settings and then click Control Panel...

Страница 290: ...art the system in such case the memory dump may not be stored correctly Follow the procedure below to specify the memory dump 1 Select Control Panel and click System The System Properties dialog box a...

Страница 291: ...before adding memory The size of debugging information memory dump changes when add ing memory Check the size of the empty space in the debugging information memory dump write destination drive 4 Spe...

Страница 292: ...and logs the diagnostic information log Follow the procedure below to instruct Dr Watson to collect diagnostic information 1 Click Run on Start menu 2 Type drwtsn32 exe in the Open box and click OK Th...

Страница 293: ...ws Component The Windows Components Wizard dialog box appears 4 Click Management and Monitoring Tools and then click Details The Management and Monitoring Tools dialog appears 5 Click to select the Ne...

Страница 294: ...Maintenance Utilities Various maintenance utilities are included in your ExpressBuilder See Appendix 7 Installing and Using Utilities on page 337 for more information on installing the utilities to y...

Страница 295: ...ur system you do not have to apply the Service Pack 2 again Updating the System is automatically executed by Express Setup Execute Updating the System in following cases Modified system configuration...

Страница 296: ...he OEM FD This is not a standard procedure The detailed information is provided by the manual of the Mass Storage Device Installation of a Mass storage device not supported by Express Setup If you wou...

Страница 297: ...ion media No Service Pack Windows Server 2003 OS installation media with Service Pack 1 OS installation media with Service Pack 1 Service Pack 2 Installing Service Pack You can install the Service Pac...

Страница 298: ...ices to the server before installing the operating system Floppy Disk Drive No internal floppy disk drive is included in your system Prepare an optional USB floppy disk drive if necessary About the Up...

Страница 299: ...ize large enough to store the dump file in the boot drive is required It may be impossible to collect correct debugging information due to a virtual memory shortage if the paging file is insuffi cient...

Страница 300: ...bull com 1 Set the Size required for installation Paging file size 2 Set the debugging information equivalent to the dump file size so that it is written to a separate disk If necessary install an ad...

Страница 301: ...LL NovaScale Server with ExpressBuilder Use this procedure if you have only the BULL NovaScale Server to create the Windows 2003 OEM Disk for ExpressBuilder If you have only the BULL NovaScale Server...

Страница 302: ...es Follow the steps below 1 Prepare a 3 5 inch floppy disks 2 Start the operating system 3 Insert the ExpressBuilder DVD in the optical device drive The Autorun menu is displayed 4 Click Create drive...

Страница 303: ...puter s hardware configuration is displayed A screen with a solid blue background is displayed Note There is no visible indication on screen when F6 has been pressed 5 When the following message is di...

Страница 304: ...ft Windows Server 2003 R2 DISC 2 after the application of System update Be sure to install Microsoft Windows Server 2003 R2 DISC 2 In this case note that the Windows Setup screen is not displayed 11 I...

Страница 305: ...end you apply this update It does not need to be applied again when the Windows Server 2003 CD ROM in which ServicePack 2 is included is installed Go on to Updating the System on page 306 Update the S...

Страница 306: ...ese version of Windows Server 2003 R2 is used 002 win winnt dotnet qfe chs kb921411 exe When the French version of Windows Server 2003 R2 is used 002 win winnt dotnet qfe fra kb921411 exe 4 When the f...

Страница 307: ...ws CD ROM that contains the Service Pack 2 you do not have to apply the Service pack 2 again 1 Log on to the system using an account administrator authority such as administrator 2 Insert the ExpressB...

Страница 308: ...ocess below 1 Start the Windows Explorer and click the Tools and Folder Options 2 Select the Files and Folders Hidden files and folders Show hidden files and folders radio button from Advanced setting...

Страница 309: ...port sys from the directory noted above to Systemdrive WINDOWS system32 drivers 5 Restart the system 6 Refer to Applying the Hotfix KB921411 on page 304 and apply the Hotfix for Windows KB921411 7 Ref...

Страница 310: ...ROSet 1 Insert the ExpressBuilder DVD into the optical device drive If the Autorun menu is displayed close the menu screen 2 The Windows Explorer dialog starts In the case of the standard start menu c...

Страница 311: ...lick Start menu point to Control Panel Administrative tools and click Computer Management and then double click the Network Adapter Name in the Network Adapter list Procedure with the classic start me...

Страница 312: ...e an additional graphics card make sure to remove its corresponding driver Should it be necessary to install manually the drivers follow the procedure below 1 Insert the ExpressBuilder DVD into the Op...

Страница 313: ...Driver 4 When the Update Device Driver Wizard appears select No not this time and click Next 5 Select Install from a list or specific location Advanced and click Next 6 Select Don t search I will choo...

Страница 314: ...ation process is as follows Note The activation process is not required for Windows Server 2003 R2 1 Click Run on Start menu Type the following in the Open box and click OK oobe msoobe a Figure 158 Ru...

Страница 315: ...User Guide 314 www bull com 3 Follow the on screen messages to proceed with the activation...

Страница 316: ...User Guide 315 www bull com Available Switch Options for the Windows Server 2003 Boot ini File Refer to Available switch options for the Windows Server 2003 Boot ini file on page 288...

Страница 317: ...User Guide 316 www bull com Setting for Collecting Memory Dump Debug Information Use the procedure described in Memory Dump Debug Information on page 289...

Страница 318: ...rvice Pack 2 OS installation media No Service Pack Installing Service Pack You can install the Service Pack on the server If the Service Pack is not attached to your system prepare it yourself Updatin...

Страница 319: ...file system will not be converted normally Disconnect the MO device and restart the installation from the beginning Media such as DAT Do not connect such devices to the server before installing the op...

Страница 320: ...ugging information due to a virtual memory shortage if the paging file is insuffi cient so we recommend you set a paging file large enough for the entire system Regardless of the size of the mounted m...

Страница 321: ...eating from the menu which appears when running BULL NovaScale Server with ExpressBuilder Use this procedure if you have only the BULL NovaScale Server to create the Windows 2003 OEM Disk for ExpressB...

Страница 322: ...Follow the steps below 1 Prepare a 3 5 inch floppy disks 2 Start the operating system 3 Insert the ExpressBuilder DVD in the optical device drive The Autorun menu is displayed 4 Click Create drive di...

Страница 323: ...in one of the following states Setup is inspecting your computer s hardware configuration is displayed A screen with a solid blue background is displayed Note There is no visible indication on screen...

Страница 324: ...64 Edition DISC 2 In this case note that the Windows Setup screen is not displayed 12 Insert Microsoft Windows Server 2003 R2 x64 Edition DISC 2 CD ROM into the optical disc drive Confirm the paramete...

Страница 325: ...11 Caution In the situation below make sure to update the system and to apply the Hotfix KB921411 Modified system configuration Recovered the system using recovery process Note If you use Windows Serv...

Страница 326: ...message is displayed make sure to click Finish to restart the system Figure 162 Software Update Installation Wizard The Hotfix KB921411 was successfully applied Updating the System The System Update a...

Страница 327: ...Autorun Menu is displayed 3 Left click on Setup Windows and then click Update the system Note You can also right click on the Autorun Menu Follow the on screen messages to proceed The OK dialog box is...

Страница 328: ...w file type Hide protected operating system files Recommended When the message You have chosen to display protected operating system files is displayed click Yes 4 Make sure of the files Open System d...

Страница 329: ...ained in the network driver Using PROSet enables the following items Verify detailed information of the adapter Diagnose loop back test packet transmission test and so on Setup of teaming Configuring...

Страница 330: ...l Panel Network Connections and Local Area Connection Procedure with the classic start menu a Click Start menu Click Settings and Click Network Connections The Network Connections dialog box is displa...

Страница 331: ...lude this location in the search check box and and specifiy the correct path 6 Click Next 7 Click Finish Re install the Network Driver The network driver will be installed automatically Optional Netwo...

Страница 332: ...Fault Tolerance AFT is a feature that creates a group containing more than one adapter and converts the process of the working adapter to the other adapter in the group when any trouble occurred on t...

Страница 333: ...ter Fault Tolerance or Adaptive Load Balancing and click Next 5 Click Finish 6 If it is necessary to set the adapter priority setting follow the steps below Otherwise go through to step 7 a Click the...

Страница 334: ...matically Installing a RAID controller Driver LSILogic MegaRAID SAS 8480E Troubleshooting The driver may sometimes not be installed during the OS installation In this case please install the driver as...

Страница 335: ...ed before it can be used The Windows activation process is as follows 1 Click Run on Start menu Type the following in the Open box and click OK oobe msoobe a Figure 163 Run Dialog Box 2 When the scree...

Страница 336: ...User Guide 335 www bull com 3 Follow the on screen messages to proceed with the activation Figure 165 Windows Activation Screen 2...

Страница 337: ...User Guide 336 www bull com Setting for the Memory Dump Collection Debug Information Use the procedure described in Memory Dump Debug Information on page 289...

Страница 338: ...uide 337 www bull com Appendix 7 Installing and Using Utilities This section describes how to use the ExpressBuilder DVD that comes with your server and to install the utilities stored on the ExpressB...

Страница 339: ...elps you install the Operating system the Management software or use the maintenance utilities When you insert the ExpressBuilder disk into the DVD drive and reboot the system the following menu appea...

Страница 340: ...ss Setup see Appendix 4 Installing the Operating System with Express Setup on page 264 or the following functions from this menu Create the OEM Disk You can create the Windows OEM Disk to use at the W...

Страница 341: ...OS Startup FD is used to start the ROM DOS system See ROM DOS startup FD on page 238 Test and diagnostics This function allows you to diagnose this computer See Test and diag nostics on page 238 Maint...

Страница 342: ...indows XP Vista or Win dows Server 2003 or later Some documents are provided in PDF format Use the Adobe Reader to view or print these documents If the menu does not appear select My computer by using...

Страница 343: ...m We recommend you create a Parameters file to setup the servers from the ExpressBuilder When using a floppy disk a USB floppy disk drive is required Caution You cannot create a Parameters file for Mi...

Страница 344: ...User Guide 343 www bull com 3 Right click on the screen or left click Setup Windows The menu displayed below appears 4 Click Parameter File Creator...

Страница 345: ...User Guide 344 www bull com The Parameter File Creator is displayed 5 Load Parameters step is displayed Select Do not load parameters from the menu and click Next...

Страница 346: ...User Guide 345 www bull com 6 Select the Operating System to install Select Install the Windows 32bit editions from the menu and click Next...

Страница 347: ...meter File Creator displays the upper limit that the RAID controller can support The total of The number of physical devices used to create the logical drive and The number of the physical devices spe...

Страница 348: ...User Guide 347 www bull com 8 Specify the installation medium and the Windows system partition The Specify medium Partitions step is displayed Confirm the parameters modify if necessary and click Next...

Страница 349: ...s the contents of the hard disk will be all deleted If Use existing partitions is selected ExpressBuilder installs the Operating System to the 1st partition the 1st par tition contents are deleted The...

Страница 350: ...license mode The Enter basic parameters step is displayed Confirm the parameters modify if necessary and click Next Caution The Computer name and User name are required parameters Note Even if you do...

Страница 351: ...ings The Enter Network Protocol step is displayed Confirm the parameters modify if necessary and click Next 11 Enter the domain or workgroup name to be used The Enter domain and account step is displa...

Страница 352: ...o install The Select Windows component step is displayed Confirm the parameters modify if necessary and click Next 13 Select the applications to install The Setting applications step is displayed Conf...

Страница 353: ...s The Save parameters step is displayed If you want to save the parameters set the free formatted floppy disk Select Save parameters enter the file path of the parameters files into the text box and c...

Страница 354: ...created Click Yes to exit the Parameter File Creator Notes If you wish to modify the existing information file parameters file click Load Parameters at the Load Parameters screen Refer to the help to...

Страница 355: ...ly system operation system extension and transfer tasks Some features of NEC ESMPRO Manager include Hardware and software server configuration Hardware resources mounted in servers such as the CPU mem...

Страница 356: ...aScope is a software used for the remote management of the BULL NovaScale series See the online documentation for details on the functions and installation of NEC DianaScope Note You need the server l...

Страница 357: ...Windows Before installing the Universal RAID Utility you need to install the following software Microsoft NET Framework 2 0 The Runtime component of the Microsoft Visual C 2005 SP1 This software is pr...

Страница 358: ...oller via network If you want to manage it via network please use the function of remote console ex Remote Desktop of Windows Easy Configuration You can not use the function of Easy Configuration to L...

Страница 359: ...nent was purchased Be sure to record the same information for any components added to the system such as a power supply hard disk drives add in boards or printers Record the model and serial numbers o...

Страница 360: ...Serial No Date installed Monitor Type Model name Serial No Date installed Hard Disk 1 Type Serial No Capacity Date installed Type number 2 Type Serial No Capacity Date installed Type number 3 Type Se...

Страница 361: ...ed Additional cabinet for disk Model name Serial No Date installed External Peripheral Device 1 Model name Serial No Manufacturer Date installed External Peripheral Device 2 Model name Serial No Manuf...

Страница 362: ...com Software Firmware version OS Application of RUR media Apply Name Name Version Version File system FAT HPFS NTFS Others Bundled software installed Licensed software installed Application running w...

Страница 363: ...mailing address below NAME __________________________________________________________ DATE ______________ COMPANY ___________________________________________________________________________ ADDRESS __...

Страница 364: ..._____________________________ DATE ______________ COMPANY ___________________________________________________________________________ ADDRESS __________________________________________________________...

Страница 365: ......

Страница 366: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 83EV 00...

Отзывы: