SYSTEM Error E11
Fan Failure
An error occurred in the fan speed.
C h e c k t h a t n o f o r e i g n
objects or dust are clog-
ging the fan. If any foreign
objects or dust are found,
use a pair of tweezers, air
duster, or other tool to
remove them. If the error
is displayed again, contact
Buffalo technical support
for assistance.
SYSTEM Error E12
Cooling Failure
A rise in the system temperature may have ex-
ceeded the allowable safety value.
Do not place objects in the
area around the TeraStation.
Also, move the TeraStation
to a cool location.
RAID Arrayx E14
Can't Mount
RAID array X cannot be mounted.
Run the RAID array disk
check in the TeraStation's
Web Admin interface.
HDx Error E16
HDx Not Found
Unable to fi nd hard drive X.
Hard drive X may be discon-
nected or may have failed.
After shutting down, rein-
stall the hard drive.
HDx Error E22
HDx Can't Mount
Mounting of hard drive X failed.
Format the hard drive. After
formatting, if the error still
appears after rebooting,
replace the hard drive. If
the error is displayed again,
contact Buffalo technical
support for assistance.
FailOver E27
LostBackupTarget
Unable to fi nd the backup TeraStation.
From the main TeraStation's
Web Admin interface, navi-
gate to [Backup] - [Failover]
to reconfigure the backup
TeraStation for failover.
HDx Broken E30
Replace the DISK
An error occurred, so hard drive X was removed
from the RAID array.
Replace hard drive X.