background image

Momentus 7200.1 PATA

ST910021A

 

ST980825A

 

ST96023A

 

ST94015A

Содержание ST94015A

Страница 1: ...Momentus 7200 1 PATA ST910021A ST980825A ST96023A ST94015A ...

Страница 2: ......

Страница 3: ...Momentus 7200 1 PATA ST910021A ST980825A ST96023A ST94015A ...

Страница 4: ... Technology LLC SeaTools SeaFONE SeaBOARD and SeaTDD are either registered trademarks or trademarks of Seagate Technology LLC Other product names are registered trademarks or trademarks of their owners Seagate reserves the right to change without notice product offerings or specifications No part of this publication may be reproduced in any form without written permission of Seagate Technology LLC...

Страница 5: ...Revision status summary sheet Revision Date Sheets Affected Rev A 05 17 05 All Rev B 09 18 06 Page 6 Section 2 5 and pages 27 30 Section 5 0 ...

Страница 6: ......

Страница 7: ...perature gradient 11 2 10 3 Humidity 11 2 10 4 Altitude 11 2 10 5 Shock 12 2 10 6 Vibration 12 2 11 Acoustics 13 2 12 Electromagnetic immunity 13 2 13 Reliability 14 2 14 Agency certification 14 2 14 1 Safety certification 14 2 14 2 Electromagnetic compatibility 14 2 14 3 FCC verification 15 2 15 Environmental protection 16 3 0 Configuring and mounting the drive 17 3 1 Handling and static discharg...

Страница 8: ...vi Momentus 7200 1 PATA Product Manual Rev B ...

Страница 9: ...roduct Manual Rev B vii List of Figures Figure 1 Momentus 7200 1 PATA disc drive 1 Figure 2 Typical 5V startup and operating current profile 9 Figure 3 Jumper settings 17 Figure 4 Mounting dimensions top side and end view 18 ...

Страница 10: ...viii Momentus 7200 1 PATA Product Manual Rev B ...

Страница 11: ... second using Ultra DMA mode 5 Giant magnetoresistive GMR recording heads and EPRML technology which provide the drives with increased areal density State of the art cache and on the fly error correction algorithms Full track multiple sector transfer capability without local processor intervention 800 Gs nonoperating shock 250 Gs operating shock SeaTools diagnostic software performs a drive self t...

Страница 12: ...2 Momentus 7200 1 PATA Product Manual Rev B ...

Страница 13: ...0 Bytes per sector 512 Physical read write heads 4 4 3 2 Discs 2 2 2 1 Cache Mbytes 8 Recording density BPI bits inch max 700 000 Track density TPI tracks inch max 114 000 Areal density Bbits inch2 max 81 Spindle speed RPM 7 200 Internal data transfer rate OD Mbits sec max 539 Sustained data transfer rate OD Mbytes sec 45 8 I O data transfer rate Mbytes sec max 100 ATA data transfer modes supporte...

Страница 14: ... 2 msec 250 Shock nonoperating Gs max at 2 msec 800 Shock nonoperating Gs max at 1 msec 900 Shock nonoperating Gs max at 0 5 msec 400 Vibration operating max displacement may apply below 10 hz 1 0 Gs 0 to peak 5 500 Hz Vibration nonoperating max displacement may apply below 22 hz 5 0 Gs 0 to peak 5 500 Hz Drive acoustics sound power bels Idle 2 5 typical 2 8 max Seek 2 9 typical 3 1 max Nonrecover...

Страница 15: ...umber of guaranteed sectors as defined above 2 4 Physical organization Model Formatted capacity Guaranteed sectors Bytes per sector ST910021A 100 Gbytes 195 371 568 512 ST980825A 80 Gbytes 156 301 488 512 ST96023A 60 Gbytes 117 210 240 512 ST94015A 40 Gbytes 78 140 160 512 Cylinders Read write heads Sectors per track 16 383 16 63 Model Read write heads Number of discs ST910021A 4 2 ST980825A 4 2 S...

Страница 16: ...tracks inch max 114 000 Areal density Gbits inch2 max 81 Spindle speed RPM 0 2 7 200 Internal data transfer rate OD Mbits sec max 539 Sustained data transfer rate OD Mbytes sec max 45 8 I O data transfer rate Mbytes sec max 100 Ultra DMA mode 5 Interleave 1 1 Cache buffer 8 Mbytes 8 192 kbytes Height mm inches 9 5 0 2 0 374 0 0078 Width mm inches 69 85 0 25 2 75 0 0098 Length mm inches 100 2 0 25 ...

Страница 17: ...rhead Measured in performance mode Note These drives are designed to consistently meet the seek times represented in this manual Physical seeks regardless of mode such as track to track and average are expected to meet or exceed the noted values However due to the manner in which these drives are formatted benchmark tests that include command overhead or measure logical seeks may produce results t...

Страница 18: ...ad write power and current Read write power is measured with the heads on track based on three 63 sector read or write operations every 100 msecs Operating power and current Operating power is measured using 40 percent random seeks 40 percent read write mode 1 write for each 10 reads and 20 percent drive idle mode Idle mode power Idle mode power is measured with the drive up to speed with servo el...

Страница 19: ... host system power supply across an equivalent 15 ohm resistive load on the 5 volt line Using 5 volt power the drive is expected to operate with a maximum of 100 mV peak to peak square wave injected noise at up to 10 MHz Note Equivalent resistance is calculated by dividing the nominal voltage by the typical RMS read write current 2 9 3 Voltage tolerance Voltage tolerance including noise 5V 5 ...

Страница 20: ...c access is necessary Sleep mode The drive enters Sleep mode after receiving a Sleep command from the host In Sleep mode the drive buffer is in Self Refresh Low Power mode the heads are parked and the spindle is at rest The drive leaves Sleep mode after it receives a Hard Reset or Soft Reset from the host After receiving a reset the drive exits Sleep mode and enters Standby mode with all current t...

Страница 21: ...arly by 1 C every 1000 feet 2 10 2 Temperature gradient 2 10 3 Humidity 2 10 3 1 Relative humidity 2 10 3 2 Wet bulb temperature 2 10 4 Altitude Operating 5 to 55 C 41 to 131 F Nonoperating 40 to 70 C 40 to 158 F Operating 20 C per hour 68 F per hour max without condensation Nonoperating 30 C per hour 86 F per hour max Operating 8 to 90 noncondensing 30 per hour max Nonoperating 5 to 95 noncondens...

Страница 22: ...ubsequently put into operation is 900 Gs based on a nonrepetitive half sine shock pulse of 1 msec duration The nonoperating shock level that the drive can experience without incurring physical damage or degradation in performance when subsequently put into operation is 400 Gs based on a nonrepetitive half sine shock pulse of 0 5 msec duration 2 10 6 Vibration All vibration specifications assume th...

Страница 23: ...When properly installed in a representative host system the drive operates without errors or degradation in performance when subjected to the radio frequency RF environments defined in the following table Table 4 Drive level acoustics Acoustic mode Idle Seek 2 5 bels typ 2 8 bels max 2 9 bels typ 3 1 bels max Table 5 Electromagnetic immunity Test Description Performance level Reference standard El...

Страница 24: ...at all systems will comply with the directives The drive is designed for operation inside a properly designed enclosure with properly shielded I O cable if necessary and terminators on all unused I O ports Computer manufacturers and system integrators should confirm EMC compliance and provide CE marking for their products Measurement type Specification Nonrecoverable read errors 1 per 1014 bits re...

Страница 25: ...ure not attached as an external device As such each drive is considered to be a subassembly even when it is individually mar keted to the customer As a subassembly no Federal Communications Commission verification or certification of the device is required Seagate Technology LLC has tested this device in enclosures as described above to ensure that the total assembly enclosure disc drive motherboa...

Страница 26: ...lication num ber 004 000 00345 4 2 15 Environmental protection Seagate designs its products to meet environmental protection requirements worldwide including regulations restricting certain chemical substances European Union Restriction of Hazardous Substances RoHS A new law the European Union Restriction of Hazardous Substances RoHS directive will restrict the pres ence of chemical substances inc...

Страница 27: ...cedure Handle the drive only by its edges or frame The drive is fragile handle it with care Do not press down on the drive top cover Always rest the drive on a padded antistatic surface until you mount it in the computer Do not touch the connector pins or the printed circuit board Do not remove the factory installed labels from the drive or cover them with additional labels Removal voids the warra...

Страница 28: ...nsions Follow these important mounting precautions when mount ing the drive Allow a minimum clearance of 0 030 inches 0 76 mm around the entire perimeter of the drive for cooling Use only M3 UNC mounting screws Do not overtighten the mounting screws maximum torque 4 0 inch lb Four 4 threads 0 080 inches minimum screw engagement recommended Figure 4 Mounting dimensions top side and end view 157 3 9...

Страница 29: ...tor pins The following table summarizes the signals on the 44 pin ATA interface connector For a detailed description of these signals refer to the Draft ATA 6 Standard Table 6 Connector signals Signal Name Connector Contact Cable Conductor Cable Conductor Connector Contact Signal Name RESET 1 1 2 2 Ground DD7 3 3 4 4 DD8 DD6 5 5 6 6 DD9 DD5 7 7 8 8 DD10 DD4 9 9 10 10 DD11 DD3 11 11 12 12 DD12 DD2 ...

Страница 30: ...Device Diagnostics 90H Flush Cache E7H Flush Cache Extended EAH Format Track Legacy 50H Identify Device ECH Idle 97H E3H Idle Immediate 95H E1H Initialize Device Parameters 91H Read Buffer E4H Read DMA C8H C9H Read DMA Extended 25H Read Log Extended 22H Read Multiple C4H Read Multiple Extended 29H Read Native Max Address F8H Read Native Max Address Extended 27H Read Sectors 20H 21H Read Sectors Ex...

Страница 31: ...Standby Immediate 94H E0H Vendor Unique 9AH FAH FBH Write Buffer E8H Write DMA CAH CBH Write DMA Extended 35H Write Log Extended 32H Write Multiple C5H Write Multiple Extended 39H Write Sectors 30H 31H Write Sectors Extended 34H ATA standard power management commands Check Power Mode 98H or E5H Idle 97H or E3H Idle Immediate 95H or E1H Sleep 99H or E6H Standby 96H or E2H Standby Immediate 94H or E...

Страница 32: ...22 Momentus 7200 1 PATA Product Manual Rev B Security Freeze Lock F5H Security Disable Password F6H Table 7 Supported commands Command name Command code in hex ...

Страница 33: ...6 383 2 ATA reserved 0000H 3 Number of logical heads 16 4 Retired 0000H 5 Retired 0000H 6 Number of logical sectors per logical track 63 003FH 7 9 Retired 0000H 10 19 Serial number 20 ASCII characters 0000H none ASCII 20 Retired 0000H 21 Retired 0400H 22 Obsolete 0000H 23 26 Firmware revision 8 ASCII character string padded with blanks to end of string x xx 27 46 Drive model number 40 ASCII charac...

Страница 34: ...flow control 240 nsec 00F0H 68 Minimum PIO cycle time with IORDY flow control 120 nsec 0078H 69 74 ATA reserved 0000H 75 Queue depth 0000H 76 79 ATA reserved 0000H 80 Major version number 007EH 81 Minor version number 0000H 82 Command sets supported 346BH 83 Command sets supported 7D01H 84 Command sets support extension 4003H 85 Command sets enabled 34xxH 86 Command sets enabled 3xxxH 87 Command s...

Страница 35: ... is currently active 10 Multiword DMA mode 2 is currently active Bit Word 88 0 Ultra DMA mode 0 is supported 1 Ultra DMA mode 1 is supported 2 Ultra DMA mode 2 is supported 3 Ultra DMA mode 3 is supported 4 Ultra DMA mode 4 is supported 8 Ultra DMA mode 0 is currently active 9 Ultra DMA mode 1 is currently active 10 Ultra DMA mode 2 is currently active 11 Ultra DMA mode 3 is currently active 12 Ul...

Страница 36: ...set the default values of the features are as indi cated above Table 8 Features register values 02H Enable write cache default 03H Set transfer mode based on value in Sector Count register Sector Count register values 00H Set PIO mode to default PIO mode 2 01H Set PIO mode to default and disable IORDY PIO mode 2 08H PIO mode 0 09H PIO mode 1 0AH PIO mode 2 0BH PIO mode 3 0CH PIO mode 4 default 20H...

Страница 37: ...ns and other channel related information To learn more about the ben efits or to register go to spp seagate com any time from anywhere in the world Seagate Service Centers Presales Support Our Presales Support staff can help you determine which Seagate products are best suited for your specific application or computer system as well as product availability and compatibility Technical Support Seaga...

Страница 38: ...1 1 405 324 4704 Technical Support Call center Toll free Direct dial FAX Americas 1 800 SEAGATE2 1 405 324 47002 1 405 324 3339 Customer Service Operations Warranty Service Call center Toll free Direct dial FAX E mail USA Canada Mexico and 1 800 468 34723 1 956 664 4725 Latin America Brazil Jabil Industrial Do Brasil 55 11 4191 4761 55 11 4191 5084 LTDA4 SeagateRMA br jabil com Data Recovery Servi...

Страница 39: ... France 00 800 47324283 00 800 47324289 Germany 00 800 47324283 00 800 47324289 Ireland 00 800 47324283 00 800 47324289 Italy 00 800 47324283 00 800 47324289 Netherlands 00 800 47324283 00 800 47324289 Norway 00 800 47324283 00 800 47324289 Poland 00 800 311 12 38 00 800 311 12 38 Spain 00 800 47324283 00 800 47324289 Sweden 00 800 47324283 00 800 47324289 Switzerland 00 800 47324283 00 800 473242...

Страница 40: ...Friday Seagate Service Centers Call center Toll free Direct dial FAX Australia 1800 14 7201 China Mandarin 1 4 800 810 9668 86 10 6225 5336 Hong Kong 800 90 0474 Hong Kong Cantonese 1 4 001 800 0830 1730 India2 4 1 800 180 1104 Indonesia 001 803 1 003 2165 Japan3 4 0034 800 400 554 Korea3 4 007 98 8521 7635 Malaysia 1 800 80 2335 New Zealand 0800 443988 Singapore 800 1101 150 65 6488 7525 Taiwan M...

Страница 41: ... discs 5 dissipation 8 Download Microcode 20 drive diagnostics 7 drive monitoring 1 drive self test 1 E electrical fast transient 13 electromagnetic compatibility 14 Electromagnetic Compatibility Directive 14 electromagnetic immunity 13 electrostatic discharge 13 EMC compliance 14 EN 60950 14 enclosures 15 environmental specifications 11 EPRML 1 error correction algorithms 1 errors 14 European Uni...

Страница 42: ...recautions 18 programmable power management 10 R radiated RF immunity 13 radio and television interference 15 random track location 8 Read Buffer 20 Read DMA 20 Read DMA Extended 20 read errors 14 Read Multiple 1 20 Read Multiple Extended 20 Read Native Max Address 20 Read Native Max Address Extended 20 Read Sectors 20 Read Sectors Extended 20 Read Verify Sectors 20 Read Verify Sectors Extended 20...

Страница 43: ...utions 17 subassembly 15 support services 27 surge immunity 13 T technical support services 27 temperature 11 temperature gradient 11 time to ready 7 timers 10 track density 6 track to track seek time 7 TUV North America 14 U UL 1950 14 V vibration 12 voltage 9 voltage dips interrupts 13 voltage tolerance 9 W Warranty 14 weight 6 wet bulb temperature 11 width 6 Write Buffer 21 Write DMA 21 Write D...

Страница 44: ...36 Momentus 7200 1 PATA Product Manual Rev B ...

Страница 45: ......

Страница 46: ...Seagate Technology LLC 920 Disc Drive Scotts Valley California 95066 4544 USA Publication Number 100320518 Rev B Printed in USA ...

Отзывы: