Section Rev. February 2009
Section 6: Troubleshooting
6-9
CODE EXTENDED
CODE*
FAILURE DESCRIPTION
POSSIBLE CAUSES
50
51
52
53
54
55
56
57
58
59
Detect10
Detect1
Detect2
Detect3
Detect4
Detect5
Detect6
Detect7
Detect8
Detect9
PIN NOT DETECTED IN DIAGNOSTICS -
These ten codes are
used during Machine Cycling
diagnostics only. If a standing pin is not
detected when the pinsetter is
operating in this mode, the pinsetter will
stop and display the code for the pin
not detected. To activate this option set
the Enable 50 Err setup option to "Y"
1.
2.
3.
4.
5.
Check the pin detector plate for proper positioning. Is it level from left to right.
Check the Stroke Limiter height adjustment.
Check the setting table levelness.
Check the angle "1" and "2" adjustment.(Pinsetter Timing)
Check stroke limiter shock.
60
A Found
SWITCH A NOT EXPECTED BUT
FOUND - Pinsetter CPU has requested
that the table be lowered but the "A"
switch is still being held closed.
1.
2.
3.
4.
Table Motor or brake defective preventing table from being lowered.
The wiring between the switch and P-1/P-23 on the Nexgen Controller is
defective.
Bad Connection on the H.V. PCB or Bad H.V. PCB (Nexgen)
Faulty A-Switch
61
B Found
SWITCH B NOT EXPECTED BUT
FOUND - This switch was actuated at the
wrong time or continuously.
1.
2.
Switch "B" on the switch cluster is shorted. Check the wiring and the switch.
Table motor or brake defective
62
C Found
SWITCH C NOT EXPECTED BUT
FOUND - This switch was actuated at the
wrong time or continuously.
1.
2.
Switch "C" on the switch cluster is shorted. Check the wiring and the switch.
Nexgen CPU defective. Check the wiring and swap the PCBs with a working
lane pair.
Table motor or brake defective.
63
D Found
SWITCH D NOT EXPECTED BUT
FOUND - This switch was actuated at the
wrong time or continuously.
1.
2.
3.
Switch "D" on the switch cluster is shorted. Check the
wiring and the switch.
Table motor or brake defective
Nexgen CPU defective. Check the wiring and swap the PCBs with a working
lane pair.
64
SMFound
SWITCH SM NOT EXPECTED BUT
FOUND - This sweep motor switch is
actuated when it should not have been.
1.
2.
3.
4.
5.
Sweep motor defective.
Sweep motor brake defective or stuck on the motor shaft.
No power to the sweep motor and/or brake. Check wiring
for damage and proper hookup.
"SM" switch shorted. Wiring between the Nexgen Controller and the switch is
shorted.
Sweep wagon or sweep arms binding or roller out of adjustment.
Содержание GS-X Series
Страница 1: ...Operations Service Manual GS X Pinsetter with Advanced CE Guarding March 2017 47 902748 000...
Страница 4: ...2 Safety Section Section Rev February 2017 Intentionally Blank Page...
Страница 15: ...Section Rev February 2017 Safety Section 13 GS Safetty Mirror Safety Mirror...
Страница 36: ...1 2 Section 1 Operations Section Rev February 2009 Intentionally Blank Page...
Страница 51: ...Section Rev February 2009 Section 1 Operations 1 17 Figure 1 14 Setting New Pins...
Страница 68: ...2 2 Section 2 Electronics Switches Solenoids and Motors Section Rev December 2016 Intentionally Blank Page...
Страница 94: ...3 2 Section 3 Nexgen Electronics Section Rev February 2017 Intentionally Blank Page...
Страница 125: ...Section Rev February 2017 Section 3 Nexgen Electronics 3 33 Safety Controller Codes Version I And II Table 5...
Страница 131: ...Section Rev February 2017 Section 3 Nexgen Electronics 3 39 Intentionally Blank...
Страница 134: ...3 42 Section 3 Nexgen Electronics Section Rev February 2017 Intentionally Blank Page...
Страница 136: ...3 44 Section 3 Nexgen Electronics Section Rev February 2017 Back of 11 x 17 Here...
Страница 150: ...3 58 Section 3 Nexgen Electronics Section Rev February 2017 Intentionally Blank Page...
Страница 152: ...4 2 Section 4 Pinsetter Cycles Section Rev February 2009 Intentionally Blank Page...
Страница 158: ...4 8 Section 4 Pinsetter Cycles Section Rev February 2009 Figure 4 5 Pinsetter Cycles...
Страница 176: ...5 2 Section 5 Adjustments Section Rev February 2017 Intentionally Blank Page...
Страница 226: ...6 2 Section 6 Troubleshooting Section Rev February 2009 Intentionally Blank Page...
Страница 246: ...6 22 Section 6 Troubleshooting Section Rev February 2009 Intentionally Blank...
Страница 257: ...Section Rev February 2009 Section 7 Preventative Maintenance 7 11...
Страница 284: ...7 38 Section 7 Preventative Maintenance Section Rev February 2009...
Страница 286: ...8 2 Section 8 Servicing Section Rev February 2009 Intentionally Blank Page...