Section Rev. February 2017
Section 3: Nexgen Electronics
3-21
Enable 50 ERR (Y or N) -
This selection allows pinfall detection to be
monitored or ignored during machine cycle diagnostics.
Y -
Enable Codes (default)
N -
Disable Codes
Enable Foul: (Y or N) -
This selection allows you to accept or ignore the
foul signal coming from the foul unit.
Y -
The pinsetter will accept the foul signal (default)
N -
Foul Signals are ignored.
Dist Slow Start: (Y or N) -
The selection determines whether the
distributor will start slowly and gradually increase speed or start at full
speed. The suggested setting for this option is ”N”. This selection is
available on machines beginning with software version 4.08.02. It was
been removed for software versions 4.95.21 and later.
Y -
Slow start enabled
N -
Slow start is disabled (default)
Long Err Codes: (Y or N) -
This selection is available on machines with
software version 4.08.02 and higher. The selection determines whether
the display will show error code using the standard 2 digit code or
extended code.
Y -
Display error codes using extended format
N -
Display error codes using 2 digit format
Pinlight: (Y or N) -
This selection is available on machines with
version 4.08.02 and higher. This selection turns on the pinlight so that the
pins are illuminated even when the machine is unassigned.
Y -
Pinlight on
N -
Pinlight off (default)
Enable PF Err: (Y or N)
- This selection is available on machines with
software version 4.95.21 and higher. This selection allows the mechanic
to enable (or disable) an error code that would occur in the event that the
pinsetter loses power.
Y
- Enable the code (default)
N
- Disable the code
Off Sweep Dwn: (Y or N)
- This selection is available on machines with
software version 4.95.21 and higher.This selection causes the sweep to
drop when the lane is turned off from the scorer. The sweep will not drop
when the pinsetter is turned off via a local mechanic’s switch.
Y
- Enable sweep drop
N
- Disable sweep drop (default)
Содержание GS-X Series
Страница 1: ...Operations Service Manual GS X Pinsetter with Advanced CE Guarding March 2017 47 902748 000...
Страница 4: ...2 Safety Section Section Rev February 2017 Intentionally Blank Page...
Страница 15: ...Section Rev February 2017 Safety Section 13 GS Safetty Mirror Safety Mirror...
Страница 36: ...1 2 Section 1 Operations Section Rev February 2009 Intentionally Blank Page...
Страница 51: ...Section Rev February 2009 Section 1 Operations 1 17 Figure 1 14 Setting New Pins...
Страница 68: ...2 2 Section 2 Electronics Switches Solenoids and Motors Section Rev December 2016 Intentionally Blank Page...
Страница 94: ...3 2 Section 3 Nexgen Electronics Section Rev February 2017 Intentionally Blank Page...
Страница 125: ...Section Rev February 2017 Section 3 Nexgen Electronics 3 33 Safety Controller Codes Version I And II Table 5...
Страница 131: ...Section Rev February 2017 Section 3 Nexgen Electronics 3 39 Intentionally Blank...
Страница 134: ...3 42 Section 3 Nexgen Electronics Section Rev February 2017 Intentionally Blank Page...
Страница 136: ...3 44 Section 3 Nexgen Electronics Section Rev February 2017 Back of 11 x 17 Here...
Страница 150: ...3 58 Section 3 Nexgen Electronics Section Rev February 2017 Intentionally Blank Page...
Страница 152: ...4 2 Section 4 Pinsetter Cycles Section Rev February 2009 Intentionally Blank Page...
Страница 158: ...4 8 Section 4 Pinsetter Cycles Section Rev February 2009 Figure 4 5 Pinsetter Cycles...
Страница 176: ...5 2 Section 5 Adjustments Section Rev February 2017 Intentionally Blank Page...
Страница 226: ...6 2 Section 6 Troubleshooting Section Rev February 2009 Intentionally Blank Page...
Страница 246: ...6 22 Section 6 Troubleshooting Section Rev February 2009 Intentionally Blank...
Страница 257: ...Section Rev February 2009 Section 7 Preventative Maintenance 7 11...
Страница 284: ...7 38 Section 7 Preventative Maintenance Section Rev February 2009...
Страница 286: ...8 2 Section 8 Servicing Section Rev February 2009 Intentionally Blank Page...