F2077 Current measurement trim wrong
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
Supported by Supply Unit:
HMV01
The current measurement in the drive controller is adjusted in operation.
The adjust values are checked for compliance with the allowed tolerance.
If the values are higher the error message F2077 is generated.
Cause
Remedy
Hardware of control section or power section
defective
Replace power section or control section resp. entire
drive controller
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section or the power section.
The replacement of the entire drive controller is described in
the Project Planning Manual for the power section.