F2043 Measuring encoder: encoder signals incorrect
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The signals of the measuring system (measuring encoder) are monitored
with regard to their amplitudes and signal shape. If a signal (e.g. sin or
cos) leaves the allowed range or if the signals are disturbed in such a way
that a position error occurs, this error is generated.
Note:
As the position is no longer generated correctly when this error
is detected, it is necessary to initialize the encoder again.
Cause
Remedy
Defective encoder cable or cable shielding
Check cable to measuring system and replace it, if
necessary
Encoder defective
Check measuring system and replace it, if necessary
Faulty mounting of measuring head in the case of
linear measuring systems
Check mounting of measuring head and correct it, if
necessary
Measuring system dirty
Replace measuring system
Hardware defect on control section of drive
Replace control section or entire drive controller
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section. The replacement of the
entire drive controller is described in the Project Planning
Manual for the power section.
Note:
When using an incremental encoder with square-wave signals,
monitoring is carried out with regard to an unallowed edge.
See also
E2076 Measuring encoder: encoder signals disturbed
F2043 - Attributes
Display:
F2043
Mess. no.:
F2043 (hex)