C1214 Command only possible with linear synchronous motor
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
When executing the command for determining the commutation offset
(C1200) with the currentless procedure (see
P-0-0522,Control word for
commutation setting
) the condition for the motor type was detected not
to have been fulfilled.
Cause
Remedy
The connected motor is not a synchronous linear
motor
-
The connected motor is a synchronous linear motor,
but the wrong motor type (P-0-4014) was selected
or the pole pair distance (P-0-0018) was set to "0"
If the connected motor is a synchronous linear motor
with absolute measuring system, check the motor type
that has been set (P-0-4014) and correct it, if necessary
The connected motor is a synchronous linear motor,
the motor type (P-0-4014) was correctly set, but
there isn
’
t any absolute encoder with EnDat interface
available
If the connected motor is a synchronous linear motor
with incremental measuring system or a rotary
synchronous motor, then use the procedure with current
to determine the commutation offset (see
P-0-0522,
Control word for commutation setting
)