9-12
Command Diagnostic Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C2600 Copy IDN from internal memory to optional memory
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The command
P-0-4092, C2600 Copy IDN from internal memory to
optional memory
was started.
All parameters are copied from the internal memory (flash) to the optional
memory (MMC).
The display "C26" signals that the command is executed and the
parameters are written from the drive to the MMC.
Note:
The MMC can only be used as an optional memory for control
sections with MMC slot.
See also Functional Description "Loading, Storing and Saving
Parameters"
C2600 - Attributes
Display:
C26
Mess. no.:
C2600 (hex)
C2800 Analog input adjust command
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
By executing the command
P-0-0220, C2800 Analog input adjust
command
it is possible to carry out an automatic adjust (zero point and
gain) of the analog input.
Note:
The command is controlled by the settings in
P-0-0218,
Analog input, control parameter
.
See also Functional Description "Analog Inputs"
C2800 - Attributes
Display:
C28
Mess. no.:
C2800 (hex)