Rexroth IndraDrive
Command Diagnostic Messages
9-63
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C0250 Probe inputs incorrectly configured
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the transition check from communication phase
3 to
communication phase 4 (C0200) an error was detected.
Cause
Remedy
At least one of both probes was activated in
S-0-0169, Probe control parameter
but not
assigned to any digital input
Assign probes to digital inputs via
P-0-0300, Digital
I/Os, assignment list
,
P-0-0301, Digital I/Os, bit
numbers
and
P-0-0302, Digital I/Os, direction
Probes were accidentally activated
Deactivate probes in
S-0-0169, Probe control
parameter
See also Functional Description "Digital Inputs/Outputs"
See also Functional Description "Probe Function"
C0250 - Attributes
Display:
C0250
Mess. no.:
C0250 (hex)
C0251 Error during synchronization to master communication
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the transition check from communication phase
3 to
communication phase 4 (C0200) the drive checks whether the drive
control is synchronized to the bus interface (SERCOS, Profibus,
Interbus,
…
) via two phase control loops. The synchronization process
must have been completed until the end of the communication phase 4
transition check (C0200). If not, this error message is generated.
Cause
Remedy
Hardware defect on control section
Replace control section or entire drive controller
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section. The replacement of the
entire drive controller is described in the Project Planning
Manual for the power section.
For removing command errors see "Command Errors"
See also Functional Description "Master Communication"
C0251 - Attributes
Display:
C0251
Mess. no.:
C0251 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01