9-18
Command Diagnostic Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C0102 Limit error in parameter (-> S-0-0021)
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
Supported by Supply Unit:
HMV01
While the command
S-0-0127, C0100 Communication phase
3
transition check
is executed, the limit values (minimum/maximum value)
are checked for some parameters. An error was detected during the
execution of the command.
Cause
Remedy
Parameter values required in communication
phase 3 are outside their allowed range of values
(minimum or maximum value)
Write allowed values to parameters (cf.
minimum/maximum value) (these parameters can be
taken from list
S-0-0021, IDN list of invalid operating
data for communication phase 2
)
For removing command errors see "Command Errors"
C0102 - Attributes
Display:
C0102
Mess. no.:
C0102 (hex)
C0103 Parameter conversion error (->S-0-0021)
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
While the command
S-0-0127, C0100 Communication phase
3
transition check
is executed, the internal parameter formats are
checked in order to ensure the internal processing. An error was detected
during the execution of the command.
Cause
Remedy
Parameter values required in communication
phase 3 cannot be processed
Write allowed values to parameters (these parameters
can be taken from list
S-0-0021, IDN list of invalid
operating data for communication phase 2
)
For removing command errors see "Command Errors"
C0103 - Attributes
Display:
C0103
Mess. no.:
C0103 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01