7-112
Error Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
F2103 It was impossible to address EnDat memory
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
When addressing a memory via the EnDat bus an error occurred.
Cause
Remedy
Failure occurs sporadically (firmware error)
Clear error and contact our service department in order
to get a firmware update
Encoder cable defective or bad shielding
Clear error. Replace defective encoder cable or improve
shielding
Encoder memory or encoder electronics is defective
Clear error. Replace encoder or motor
Hardware defect on control section
Replace control section or entire drive controller
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section. The replacement of the
entire drive controller is described in the Project Planning
Manual for the power section.
See also Functional Description "Measuring Systems"
F2103 - Attributes
Display:
F2103
Mess. no.:
F2103 (hex)