C0113 Relation TNcyc (S-0-0001) to TScyc (S-0-0002) error
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the command
S-0-0127, C0100 Communication
phase 3 transition check
an error with regard to the SERCOS timing
settings was detected.
Cause
Remedy
Setting of parameters
S-0-0001, NC Cycle time
(TNcyc)
or
S-0-0002, SERCOS Cycle time (TScyc)
is incorrect
Value of
S-0-0001, NC Cycle time (TNcyc)
can only be
equal to or a multiple of
S-0-0002, SERCOS Cycle time
(TScyc)
.
Correct parameters
S-0-0001, NC Cycle time (TNcyc)
and
S-0-0002, SERCOS Cycle time (TScyc)
.
Note:
The definition of the S-0-0001 and S-0-0002 parameters is the
responsibility of the control unit manufacturer and is specified
by SERCOS.
For removing command errors see "Command Errors"