52
Frame Control Panel Operation and IP Network Setup
Changing the Mosaic Output Resolution
Changing the Mosaic Output Resolution
To change the display resolution from the Densité controller’s local control panel
1 Press the Select button on the front edge of the
output card
whose heads you wish to
configure. See
KMX-3901-OUT Front Card-edge Description
The Status LED on the selected card flashes orange, and the associated control menu
appears on the LCD display of the Densité frame’s local control panel.
2 On the local control panel, press the [–] button twice, until RESOLUTION appears on the
LCD display. See
Using the Densité Frame Control Panel
3 Press the SEL button.
HEAD 1 appears on the LCD display.
4 Press the SEL button again.
5 The current resolution for the monitor wall display that is connected to the
multiviewer’s output head 1 (i.e. through the MV OUT 1 connector) appears on the LCD
display.
6 Press the [+] and [–] buttons, to navigate to a suitable output resolution for your
monitor wall display.
7 Press SEL to apply the value shown on the LCD display.
The selected resolution is applied to the multiviewer’s output head 1.
8 Press ESC to return to the previous level in the local control menu.
HEAD 1 appears again on the display.
9 If you wish to change the resolution on the second output head (if available), then
press the [–] button.
HEAD 2 appears on the LCD display and you can repeat
above to verify
or configure the resolution of the display that is connected to the multiviewer’s output
head 2 (i.e. through the MV OUT 2 connector).
10 When you are satisfied with the selected output resolution settings, press the Select
button
on the front edge of the output card
to exit the control menu. See
IMPORTANT
Within a Kaleido-MX system, all output heads must be configured with the
same refresh rate. If your system is referenced, then the heads’ refresh rate
must also match the reference signal's refresh rate. If you must monitor 50 Hz
input signals on 60 Hz displays (or vice-versa), then do not reference your
system.
Notes
• If you do not press any button on the local control panel, the Densité
CPU-ETH2 controller will revert to its normal standby mode, and the
selected card's status LED will revert to its normal operating mode, after 30
seconds.