Distillation Process Analyzer DPA-4.5
Safety
2.7 Safety information on explosion protection
Petrochemical products
WARNING
Danger of explosions due to impermissible
petrochemical products
The explosion protection of the individual devices
has been exclusively designed for the safety
technology characteristics of the petrochemical
products specified in the order documentation.
– Before switching on and during device operation,
make sure that the supply lines and all other
petrochemical product-conveying parts of the
device only contain the permitted product (by
thorough rinsing and bleeding, for example).
– Make sure that the product properties correspond
to the given specifications.
Vent and drain
WARNING
Danger of explosions due to uncontrolled
chemical reactions
Make sure that the vent/drain system, including the
connected lines, only conveys the petrochemical
product and its exhaust gases.
Technical modifications
WARNING
Danger of explosions due to technical
modifications
Every unauthorized modification endangers the
safety of the device and can result in the failure of
the explosion protection and accidents.
– Do not make any technical modifications to the
device without prior written consent from the
manufacturer.
– Only use original replacement parts from the
manufacturer.
December 2013