Distillation Process Analyzer DPA-4.5
Dismantling
Disconnecting electrical
connections
•
Disconnect the device completely from the power supply.
•
Secure it against being switched on again.
•
Open the junction box.
•
Disconnect all cables from the terminals and pull them out of
the junction box.
•
Unscrew the cable from the potential equalization rail on the
frame.
•
Close the junction box.
11.4 Disconnecting pipe connections
Personnel
−
This work should only be conducted by a specialist for
potentially explosive atmospheres.
Personal protective equipment
−
Safety goggles
−
Safety gloves
Hazardous substances
WARNING
Danger of injury from toxic substances
Swallowing, inhaling or contact with skin or eyes
can lead to serious, permanent health damage or
death.
For this reason:
– Avoid direct exposure.
– Do not inhale vapors.
– If unknown concentrations or concentrations
above the limit values for the particular
substance are present in the air, wear suitable
respiratory protection.
– Wear appropriate protective clothing, gloves and
eye protection when working.
– In the event of an accident, consult a doctor at
once.
– Do not consume or store any food, drink or
tobacco in the work area.
154