8
Maximum Remote Station (Keypads)
3 Keypads AV-701TS, AV-701TI
5 Keypads AV-702
5 Keypads AV-707
Remote Station Current Consumption
AV-701TS:
27mA.
AV-701TI
: 36mA
AV-702:
40mA.
AV-706/7
: 60mA
Housing Dimensions
(H) 30, (D) 9, (W) 23 cm
Housing
Anodized, lockable metal box
Epoxy anti-static powder painted
Gross Shipping Weight
2.2 kg. 6 PC's per master box
Fuses: Electronic Resetable Fuses
Auxiliary Power: 1.25A
Sirens: 2 X 1.25A (fuse for each siren)
Backup Battery Fuse: 2.5A
Av-Gad Systems Ltd. reserves the right to modify and upgrade products without prior notice.
Starting version 2.09 New Fuse Included - Electronic Fuse Overview
The Electronic Fuse (resetable) device is installed as a series element in a circuit. In response to an over
current, it protects the circuit by going from a low-resistance to a high-resistance state that reduces the
current to a level that
’
s safe for the circuit elements. The change in resistance is the result of a rapid
increase in the temperature of the device. Like traditional fuses, Electronic Fuse devices interrupt the flow
of dangerous high current. But unlike traditional fuses, they automatically reset after the fault is cleared and
power to the circuit is removed. Because they are solid-state, Electronic Fuses are also able to better
withstand mechanical shock and vibration. This fuse provides reliable protection in a wide variety of
applications. In case of over current, carefully touch the fuse body (yellow round disc), hot body means the
Electronic Fuse is in protection mode, disconnect the load and wait 2-3 minutes until the fuse body gets
cooler.
Series 2000 compared to series 860
The new
Series 2000
control panels is a result of long research and exploration we at Av-Gad did among
our customers, installers and end-users requirements. In late 1998, we started the R&D and design of the
Series 2000
new systems that will keep customers smile and our QC guys happy.
Our main task was to come with 100% protected system that will ensure high reliability, more features and
flexibility.
The result is an improved system, supporting the Series 860 way of programming and wiring, but offers
great advantages of improved assembly technology and features.
The Series 2000 contains new hardware with improved EMI, RFI and Lighting protection with a complete
new telephone interface to meet all the telephone standards in the world. New zone interface with improved
Alarm and Tamper reading that use the double-zone feature, new and more efficient battery test circuit,
new siren driver and more…..
Important: Test the alarm system weekly and/or before leaving your premises.
Verify that main AC supply is connected.