49
Data Format:
This parameter describes how data is transmitted to the central station. Data Format types
are divided into 3 main groups: Extended Format, 2-digit Format (first format = type of event, second
digit = event zone) and Single Format. In all formats, Sum-Check (parity) is optional, depending on the
specifications of central station receiver.
Extended Format Reporting
: Extended Format and 2-Digit Format allow communicator to transmit an
extra digit, which provides additional information as zone number and occurred event. Program 01
(Extended) in address 207. Contact your central station for required Data Format, protocol type and
parity.
Data format ‘3 x 1’ means 3 digits for the subscriber number and 1 digit for the event.
For example:
System installed with the following transmission specifications for Tel. 2:
Subscriber number is 456 (program at address 260-262)
Report on ‘Low Battery’ selected (program at address 108 and 128)
If ‘Low Battery’ occurs, communicator will transmit:
456F - Subscriber ‘456’
FFF8 - Low Battery (‘F’ = FAULT)
Single-Digit Format Reporting:
If receiver accepts only single digit format, program 00 or 01 in
address 205, and 00 in address 207.
The data format 4 X 1 or 3 X 1 means 4 or 3 digits for subscriber number and 1 digit for event.
For example:
System installed with the same transmission information for Tel. 1, but single-digit format:
456 - Subscriber ‘456’
F = Low Battery, will report ‘456F’
Two-Digits Event Format Reporting.
Report 2-digits code for each event. Enter 02 or 03 in address
205, and 00 in address 207.
Refer to address 105 and fill out the zones to be reported, and in address 106 the events to be
reported. Default programming is useful in most cases.
Enter the alarm and restore codes in addresses 110 to 163, according to single or extended data
format transmitting.
Enter the closing and opening codes in addresses 220 to 227, according to number of users.
Forced Opening will be transmitted when Opening (disarming) the system using an inverse code.
Enter the subscriber ID (subscriber number) in addresses 260 to 283, using 3 or 4 digits according to
programmed format entered in address 205 and/or 206.
Opening and Closing Reporting to Central Station
By default (address 072) Closing/Opening reported to central station. The report contains the subscriber
ID; the Closing/Opening events, and the user number (1 to 8).
To disable reporting Closing or Opening for specific user erase the user Closing or Opening code. The
system will check for non-reporting programming and will not initiate dialing if the user is programmed
for non- reporting of Opening or Closing.