51
Quitting and updating new Programming
To exit programming mode hold down
9
Reset
.
Wait for a long beep, and then release the key.
When ‘P’ is no longer displayed, the system will revert to Disarmed mode.
Note:
Erroneous or conflicting programming features are discarded by the system upon quitting
program mode. For example: Programming the same zone as 24H type and Delayed zone will be
recognized only as a 24H zone.
Reset System to Default Codes (In case code is lost)
By factory default this feature is enabled. If user disabled it codes restore not possible. To check refer to
address 072, enter 8 in address 072.
To reset codes:
Power down by removing AC and battery, wait 30 seconds. Power up (by applying AC and Battery) and
immediately got to keypad:
Hold-down keys
*
#
Press both
together
during 4-5 seconds; wait keypad buzzer beeps. after 2
nd
beep,
release keys; ‘U’ will be displayed 3 times in confirmation.
User code No. 1 (1234) and programming code (1994) will reset to default.
2.9
Dialer - Communicator, Explanation and Programming
The Communicator is, in essence, a dialer that enables communications with a central station digital
receiver. The Communicator reports (upon programming) panel’s events such as Opening, Closing,
Alarm, and Low Battery.
The Communicator's programmable features enable compatibility with different central station
receivers. The receiver’s most important features are the Format (Radionics, Sescoa, etc.) and Data
Transfer Mode (1 x 3, 2 x 4).
The four programmable telephones (telephones 1 to 4) act as dialers, while Tel. 2 and 3 (Tel. 3 is
backup for Tel. 2) are optional as communicator or dialer.
The communicator/dialer options are programmed at addresses 201 and 202. Tel. 3 alone cannot be
programmed as communicator. At alarm, Tel. 2 and 3 will be dialed first if programmed as
communicator. Program the same reporting format for Tel. 2 and Tel. 3.
In the ‘Communicator’ mode, the panel will dial several times until the central station sends a
confirmation signal (Kiss-Off) that all the events have been transferred. The Kiss-Off signal turns the
communicator off until the next event occurs. If the number is busy, panel will re-dial automatically.
The dialing attempts number (cycles) is programmable at address 087. In case first central station
telephone number (Tel. 2) does not get Kiss-Off after several attempts, the system will dial the back-up
number - Tel. 3. Program both Tel. 2 and Tel. 3 as communicators. When system is disarmed, AC Fail
is reported 30 minuets after power fail to prevent false alarms.
To cancel the communicator dialing: Enter to Program Mode and Exit program.
Dialer
The Dialer acts similarly as the communicator, except for the panel that sends a recorded alarm tone or
vocal message with SVM module, (not a digital signal) to a regular or mobile telephone. Unlike the