![AV-GAD EasyLoader AV-2005 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/av-gad/easyloader-av-2005/easyloader-av-2005_installation-and-operation-manual_3023936023.webp)
23
Keypad Main Operations
Function
Keypad Operation
LED’s
Buzzer
Display
Siren Test
1
Siren
Hold-Down
FIRE
SHUNT
STATUS
ARMED
Long Beep
Display bypassed zones
2
Shunt
Display
Hold-Down
FIRE
SHUNT
STATUS
ARMED
Long Beep
1 2
Display troubled zones
3
Status
Hold-Down
Long Beep
1 2
Delays Delete
4
Delay
Delete
Hold-Down
FIRE
SHUNT
STATUS
ARMED
Long Beep
D
Chime On and Off
5
Chime
Hold-Down
FIRE
SHUNT
STATUS
ARMED
Long Beep
c
Follow Me Tel. Display
6
Telephone
Hold-Down
FIRE
SHUNT
STATUS
ARMED
Long Beep
C
Follow Me Tel. Programming
6
Telephone
6
Telephone
Hold-Down
FIRE
SHUNT
STATUS
ARMED
Long Beep
C
Enable Answer Now Mode
6
Telephone
1
Siren
Hold-Down
Long Beep
A
Test Zone (close all zones)
Test
7
Hold-Down
Long Beep
T
Enter to Installer Program
8
Program
Hold-Down & 1994
FIRE
SHUNT
STATUS
ARMED
Long Beep
P
Enter to Program User code
8
Program
Hold-Down & 1234
FIRE
SHUNT
STATUS
ARMED
Long Beep
u
Reset
9
Reset
Hold-Down
Long Beep
Short events log history
0
Shunt
Hold-Down
Long Beep
1 o
Time setting
0
Shunt
1
Siren
Hold-Down
FIRE
SHUNT
STATUS
ARMED
Long Beep
TIME
Date setting
0
Shunt
2
Shunt
Display
Hold-Down
FIRE
SHUNT
STATUS
ARMED
Long Beep
DATE
Panic – Hold-down both keys
*
#
Keypad Panic
FIRE
SHUNT
STATUS
ARMED
Long Beep
H
Bypass zone 3 (example)
0
Shunt
&
3
Status
FIRE
SHUNT
STATUS
ARMED
Long Beep
3
Group bypass (home mode)
0
Shunt
&
0
Shunt
FIRE
SHUNT
STATUS
ARMED
Long Beep
h
Codes Restore (at power-up)
*
#
Keypad Panic
2 Beeps
Arming with Low Battery
1
Siren
2
Shunt
Display
3
Status
4
Delay
Delete
FIRE
SHUNT
STATUS
ARMED
3 Beeps
L
Arming with troubled zone
1
Siren
2
Shunt
Display
3
Status
4
Delay
Delete
FIRE
SHUNT
STATUS
ARMED
5 Beeps
System Arming
1
Siren
2
Shunt
Display
3
Status
4
Delay
Delete
FIRE
SHUNT
STATUS
ARMED
1 Beep
System Disarming
1
Siren
2
Shunt
Display
3
Status
4
Delay
Delete
FIRE
SHUNT
STATUS
ARMED
3 Beeps
Zone bypass via code:
Press keys ‘0’, while the four LEDs are blinking enter valid user code. When
only the 2 left-most LEDs are still blinking, enter the zone number(s) to be bypassed; LEDs will stop
blinking and ‘Shunt’ LED remains on to confirm zone bypass. Note: This entire operation should be
completed within 20 seconds, or Group Bypass will be voided.
This feature is not valid with PRO
version.
0
Shunt
then hold-down
1
Siren
or
2
Shunt
Display
.
Group Bypass with Arming.
Starting version
2.17 2
nd
Group Bypass added, (address 034) and the procedure enhanced; after selecting the Group
Bypass, system is armed (without code entry). To bypass 1
st
group: Press “0” and hold-down “1”, to
bypass 2
nd
group press ”0” and hold-down “2”, to bypass both groups press “0” and hold-down “0”.
Yellow LED will flash; ‘h’ (Home) will be displayed for 1 second in confirmation, then the Armed
LED lights-up in confirmation.