sequence, code (arming with 1234 code, and disarming with 4321 code) the system will report a forced
opening (forced Disarming).
Addresses: 256 & 257.
Group Bypass (
Home Mode)
-
Group Bypass enables removal of several zones from the system. The
group of zones to be bypassed (removed) is programmable (refer to address 033).
Group Bypass is activated by pressing twice key ‘0’ prior to system Arming, Group Bypass is effective
only if system is armed within 20 seconds of ‘Group Bypass’ entry. PRO panels from version 2.16 and
upper contain two Group Bypass, 2
nd
group is at address 034.
Upon Group Bypass activation, the Yellow LED flashes, and ‘h’ (Home) is displayed for 1 second.
Groups Bypass via code is optional (refer to address 071).
Green Reset Zone
- This feature disables zones in alarm to keep alarming as long as the zone is
troubled. Useful in case of wire cut, broken sensor, etc. In such case, the zone will alarm one siren cycle
and will alarm again only after zone cleared and troubled again.
Green Reset Zone required by the environment authorities to keep the alarm noise as short as possible.
Zones programmed as a ‘Green Reset Zone,’ will not signal another alarm if the zones remain troubled.
Address: 026.
Inter Call Delay -
Time delay until dialer proceeds to next telephone number.
Address: 086. (Default value: 20)
Instant Arming
- System can be instantly armed by pressing key ‘5.’
Disable this feature if keypad is easily accessible.
Address: 071.
Lock in Arm after Tamper Alarm -
This feature will prevent Disarming when a Tamper alarm has
occurred during Armed mode.
To disarm system, enter Programming code (installer code) to unlock system, then enter a valid User
Code.
To meet required standards, use this feature, which ensures that only the Installer (system engineer) can
Disarm a system in which Tamper alarm occurred while system was Armed. Example: Prevents ‘Self-
Burglary’ by owner. Addresses: 071.
Manual Bypass (Manual Shunt) -
Any zone (1 to 8) programmed for Selective Bypass, may be
bypassed (removed from the system) by pressing key ‘0’ and then the zone number. The Yellow LED
will light up in confirmation. It is not possible to bypass all zones. Upon Disarming, all bypassed zones
will automatically become non-bypassed. Address: 035.
No EOL Resistor -
Programmed zone(s) 1 to 8, not wired with an End Of Line resistor, will be
activated upon opening the normally closed loop between the zone and common (-). To enable all zones
to be EOL type, enter ‘0’ (zero) in address 029.
Address: 029