![AV-GAD EasyLoader AV-2005 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/av-gad/easyloader-av-2005/easyloader-av-2005_installation-and-operation-manual_3023936007.webp)
7
1.5
Technical Specifications Series 2000
Operating Temperature
-10
C to 60
C
Relative Humidity
80% maximum
Input AC Power
16V AC step-down Transformer
Rated current: 1.2 Ampere
Dynamic Inner Memory
EEprom
Auxiliary Power Output
13.6 Volts +/- 5%, Regulated
Short & Overload circuit protection
Siren Outputs (x2)
Siren or Bell Selectable
Bell Mode: 13.6V DC-0.65A
Fuse protected
Siren: 8 Ohms, 20W
Dialer: Programmable 3 telephone numbers & 1
Follow-Me telephone number (4 tel. numbers).
Three tel. Interfaces are available: 600Ω, E, AS
Voice module input. Multi-format central-station
communicator. E version is TBR-21 approved, AS
version is AUSTEL approved
Pulse Dialing programmable
parameters
DTMF: Touch Tone dialing
Max. Telephone number length:
16 digits and 4 pauses.
Remote Indications on Wire Terminal
Open Collector type output
300 mA Max. @ 12V DC
EOL Zone Loop Resistor (Burglary)
EOL Zone Loop Resistor (Tamper)
2,200 Ohms, 0.25W, +/- 5%
4,700 Ohms, 0.25W, +/- 5%
Zone Loop Voltage
5 to 6.5 V DC
Zone Loop Current
3 mA with End-Of-Line Resistor
RFI and EMI protection
Zone line shorting, cutting, high
voltage lightning protection, RF Metal
Screen, Electro Static Discharge
Traps, RF Filters. Telephone line
Lighting protection circuit
Auxiliary Power (Max.)
AV-2005/8:
13.6
VDC
0.9A
Combined Aux. Power and Keypad
outputs
Battery Charging Current (Max.)
550 mA, current limitation
Battery Test: Indication at keypad or remote
indication via communicator.
Battery monitors cut-off circuit at Golden version
Performed at 0.5A load for 1 second.
Low Battery indication below 10.5V
Tested upon Arming and every 60
minutes during Armed and Disarmed
Standby Power Consumption at Disarmed mode,
and Keypad display is Off
90 mA, +/- 10 %