41
Table
: Addresses 201 to 216 indicate the communicator parameters according to your central
station's specifications. Contact the central station for full details.
Table
: Addresses 105 to 109 provide selection of the required events to be reported. For example: To
select zones 1, 2 and 6 for Zone Restore report, program 1, 2 and 6 in address 107.
Do not program if Contact ID format selected.
Table
: Addresses 110 to 257 contain the codes that will be reported for the selected events. The codes
programmed as default are recommended; you may change them according to your central station
requirements. Do not program when Contact ID format selected.
Table
: Addresses 260 to 380 contain the subscriber ID number that will be transmitted to the
central station. Follow EASY program instructions for fast code programming.
2.4
Glossary of Programmable Features
Note! A zone not programmed as a 24H, Delayed, Fire or Follower zone, is automatically
acknowledged as Instant zone
24-Hour Zone
- Zone feature. 24H zone activates alarm in both Armed and Disarmed modes, indicated
by Armed LED blinking. If 24H zone remains troubled after disarming the system a warning sounder
will sound after 10 seconds (allows the user to repair or bypass the troubled zone) from disarming. After
another 10 seconds, alarm will be triggered.
Address: 024.
AC power fail report delay -
Some installations require to report the AC fail after a while and not
immediately, specially required in areas with frequent AC fails.
AC failure will be reported if the AC power is lost for the time programmed at address 058 (default time
is 10 minutes). Programming a 0 (zero) force an instant report to the central station, and to dialer users
(if address 051-7 programmed so).
"Restore" report to the Central Station will be issued immediately after the power returns, but not if a
"Fail" report was not previously transmitted.
AC Fail report (with or without delay) is effective in Armed and Disarmed mode.
Adjustable response time -
This feature has been added in order to provide application of inertia
sensors. For zones programmed as ‘Fast Response’, the time response (sensitivity) can now be
controlled. Time response is programmed in 10 mS (milliseconds) steps at address 059. Default is 5 (50
mS). Address: 059.
Answering machine bypass -
In case the alarm panel is connected with fax or answering machine on
the same line, this feature provide to connect to the control panel for up and download. If this feature is
not enabled the fax or answering machine answers before the panel, connection is impossible.
Address 074-7.