45
Normally Open Zones -
Detectors with Normally Open (N.O.) relay can be wired without EOL
resistor. If several N.O. devices are used, they should be wired in parallel. If N.O. feature is not
programmed, N.O. devices, such as push-button, should be wired in parallel to the EOL resistor.
The N.O. relay in alarm will cause a SHORT CIRCUIT condition, which will trigger the alarm.
Address: 042.
‘Off’ Siren Time
- Determines the silent period during an alarm cycle. This feature helps prevent over-
heating sirens and electronics. This feature required by environmental agencies to prevent noise
pollution. (Recommended default value: 04).
Address: 065.
‘On’ Siren Time
- The siren period during the alarm cycle.
Programming a value of ‘0’ will render siren inaudible in all types of zones.
(Default value: 15).
Address: 064.
Outputs float at Alarm -
If programmed during alarm, the A1, ON, SLO outputs will float (if disabled
drives Low) at alarm.
Applicable most for driving wireless central station transmitters or other devices
that require non -V (max. 100 mA) when triggered. If another feature is selected for the same output,
this feature will be canceled.
Address: 073-8.
Panic Alarm
– Holding down * and # keys will trigger Keypad Panic alarm; H is displayed (zone ‘H’).
To reset the alarm enter a valid code. Stating version 2.17 selectable Panic Zone included at address
045, the default is 0. The Panic zone provides to use remote panic buttons; in previous version, only
Panic from keypad was available. Contact ID format reports Panic Zone alarm to central station. Siren
sounds. If Siren (not Bell) in use, the sound is different, not the same sound as Burglary alarm. Panic
alarm recorded in history and displayed as H (z). (Z: number of zone, 1-8). For Silent Panic alarm,
remove siren and buzzer activation by programming the Panic Zone so.
Programming Code
(Code number 9). Code 9 provides access to the Installer Programming mode.
New code can be programmed only if the current Programming Code is known.
Default programming code is ‘1 9 9 4.’
Re-Dial Cycles
- The number of times dialer or communicator will dial the programmed telephone
numbers. Address: 087. (Recommended value: 3)
Report Opening/Closing (Enable-Disable) -
This feature enables or disables the Opening and Closing
report for central station. Applicable for residential installation when Opening and Closing reports are
not required. Address: 072.
Ring Length
– Adjusting the ring detector according to the country ring frequency. Address 093.
Report Bypassed Zones at Arming (Enable-Disable)-
Insurance companies require this feature in
certain areas. Address: 072.