19
3.5
Telephone System (dialer) Dialing and Wiring
It’s recommended to connect the control panel to an independent telephone line, if a device is in
parallel with the alarm panel, this may grab the call first (like a message answer/fax) during remote
up and download. Don’t connect fax or answering machine in parallel on the same telephone line.
In case of alarm, the dialer will dial to the programmed numbers, siren sound or voice message (if
SVM-40 connected) will be transmitted to the telephone. For further details, refer to dialer &
communicator chapter 2.9. Voice module types SVM-40/60 are compatible with AV-2005/8
EasyLoader
panels
.
The voice module will apply spoken message over the telephone upon alarm.
Default dialing mode is DTMF. If Pulse dial is selected, the default is European Make/Break rate of
40/60 milliseconds (in Pulse dialing). The Make/Break rate is programmable.
Dialing mode is programmable (refer to programming sheet addresses 088 and 089).
Connect the telephone line to ‘TEL-LINE’ terminal, if handsets connected to same line connect them
to ‘PHONES’, when system attempt to dial the ‘PHONES’ is disconnected. Do not connect to ISDN
or other digital telephone system. Most ISDN converters have an Analog line; the Analog line of the
ISDN can be connected to the TEL-LINE terminal. Option: To protect the telephone line add the
Tele-Spy. The Tele-Spy it is a 24H telephone line monitor separate module. Starting version 2.17, a
software Dial Tone telephone monitor is included, refer to address 094, 051 options 5,6.
Note: To perform telephone line test enable Dial Tone detection at address 083.
For AUSTEL installations: At address 074 enter 8, at address 087 enter 2 (maximum), don’t connect
any phones in parallel with TEL-LINE terminal. Dialing problems may occur when system telephone
line is connected to Telstra Duet system or similar.
Software Telephone Line Test, address 094: Time interval between telephone line tests - in hours.
Range between 00-24. When ‘00’ programmed no test performed. Failure to get a dial tone when
dialing will cause a "Phone Line Fault" event.
3.6
SVM
–
Voice module
The
SVM-40
and
SVM-60
(replaces the SVM-24) speech modules allow the recording and playback
of two messages, with optional playback through an external speaker (not included). SVM-40
message duration is 40 seconds; SVM-60 message duration is 60 seconds. The SVM contains an on
board microphone.
The
SVM
is a
high technology device, electronically stores messages with or without power.
The
SVM
is as a digital message source in Series 2000 Alarm Control Panels, telephone dialers or in
other applications. The
SVM
supplied audio is capable to drive audio amplifier, message center,
automatic dialer or other device.
When connected to Series 2000 Alarm Control Panels, program the SVM option (at programming
table 072-7, 074-1). Follow the wiring procedures (included in SVM manual) simulate alarm, the
panel will dial first the Communicator telephone number (telephone number 2 and 3), then to other
programmed numbers. After dialing, the panel will trig the SVM to send the recorded message. If
address 071 (1) is programmed (default) Tel. 1 is erased within arming and disarming.