46
Siren Time
- Determines the duration of the alarm when zones are activated. Fire and Panic alarm
issues a modulated 2-tone siren. 24H and Burglary alarm issue a modulated 3-tone siren.
Modulated tones are disabled when Bell Mode is programmed (Address 072).
A programmed value of ‘0’ will issue an inaudible alarm.
Address: 063.
Sounder on Alarm -
This feature enables keypad sounder during alarm. When alarm is on, a modulated
tone will sound until disarming of the system.
Address: 041.
Swinger Shutdown Zone
- Zones that have been programmed as Swinger Shutdown will reset twice (3
alarm cycles). This feature prevents repeated alarms. Address: 027.
SVM (Synthesized Voice Module) Module -
Optional module that enables transmission of recorded
message upon alarm. To trigger the SVM unit, program address 072, location 7. SVM pack contains the
wiring and operating instructions.
Test Signal to Central Station (Enable-Disable) -
This feature enables setting up time of signal test,
which is transmitted by the communicator at the required time. The time is set at address 014 in a 24-
hour format.
For example: If the transmitting time is every night at midnight, enter 0000. To enable the signal test,
program ‘4’ at address 072.
Address 073 ‘2’ enables the signal test every hour. Other periodical or manual via keypad, CS tests are
not possible. (CS is shortening of Central station).
The test signal is on automatically every 24 hours to confirm that system is operative.
The system status (Armed or Disarmed) can be notified also if extended, or if 2-digit format is selected.
For example: ‘A’ in address 236 for Armed, and ‘D’ in address 254 for Disarmed.
Address: 072, 073, 236, 237, 254 and 255.
Zone In Use -
A zone programmed as an ‘In Use Zone’ enables activation of the programmed zone.
This feature eliminates the need to bypass not in use zones by wire or End of Line Resistor. Address:
020.
2.7
Programming Examples
Entering Installer (Engineer) Programming Mode
Easy Tip:
You may program any address by entering the address, followed by the value in sequence.
Power up by connecting AC power, with or without battery.
1. Hold down keypad key
8
Program
(hold-down function).
2. While four LED's are blinking, enter programming code (‘1 9 9 4’)
1
Siren
9
Reset
9
Reset
4
Delay
Delete
.