37
SYSTEM FEATURES
Feature
070
Feature
071
Enable-Siren/Bell Test upon Arming
1
Enable-Erase Follow Me number on Disarm
(1)
Enable-Keypad 3 Beeps upon Disarming
(2)
Enable-Instant Arming via Key 5
2
Enable-Sounder upon Entry Delay
(3)
Enable-Sounder during exit delay
3
Enable-Keypad Tactile Beep
*
(4)
Enable-Display Troubled Zone at Arm
*
4
Disable-4 LEDs display during Armed
5
Enable-Manual Bypass via Code No. 1
*
5
Enable-Battery Test upon Arming
(6)
Lock in Armed after Tamper Alarm
6
Enable-Code No. 7 for Access Control
7
Enable-Momentary Key-Switch
(7)
Enable-Keypad Panic
(8)
Enable-Code ‘8’ as one time code
8
Feature
072
Feature
073
Enable-Bell mode
1
Enable-Display troubled zones at Disarmed
(1)
Enable-Detailed alarm history
(2)
Enable-Test to central station every hour
2
Enable-Report Opening/Closing
(3)
Enable-Self contained Bell (0V at alarm)
**
3
Enable-Test signal to central station
4
Reset for smoke via SLO output
4
Enable-Report bypassed zones at Arming
5
Enable- Group Bypass when Arm with Key
5
Enable-Exit delay when delayed zones clear
6
Enable - 2 Siren Beeps at Key Disarming
6
Enable-’ON’ output as SVM trigger
7
Enable - A1 output time follows Siren time
7
Enable-codes reset to default by * & #
(8)
Enable - Outputs
(A1, ON, SLO)
float at active
8
Feature
074
Enable –’SLO’ output as SVM trigger
1
Enable – Auto-arming 8 timers
>
PRO only<
2
Enable –
Zone auto reset before alarm time-out
3
Enable – SLO as Pwr cut control
>PRO only<
4
Reserved – UK version (Techi Store for CS)
5
Enable – DTMF control (2008D or Ver. 3)
(6)
Bypass Answering Machine
7
Enable-Echo Cancellation Tone (AUSTEL)
8
*
(071/6) Not available with PRO
**
(073/3) self-contained Bell is operative if Bell mode selected
Note:
Features 070/4 and 071/5 are not operative with PRO panels.
In Australia program ‘8’ in address 074.
Note:
Address 074-5 is applicable for special PRO UK version, supplied with techno-store.
DIAL PARAMETERS
Pre-Dial
Delay
Wait for
Dial
Tone
Anti-Jam
Delay
Dial tone
detection
Dial
Mode
Tel.
MSG
Time
Inter-
Call
Delay
Re-Dial
Cycles
(max.)
Pulse
MAKE
Pulse
BREAK
Inter
Digit
Delay
# of
Rings
for
modem
Sec's
Sec's
Sec's
00=No
01=Yes
0=Pulses
1=DTMF
Sec's
Sec's
XX Cycle
5 mS
5 mS
50 mS
Tel. Rings
080
081
082
083
084
085
086
087
088
089
090
091
0
3
0
4
1
0
0
1
0
1
5
0
2
0
0
3
0
8
1
2
2
0
1
0
Instant
modem
answer
Ring
Cycle
Tel. Line
Test
Intervals
Min. Ring
Length
Rings Time
Out
00=No
01=Yes
100 mS
Hours
(Max 24)
10 mS
(Max 20)
Seconds
(4 to 35)
092
093
094
095
096
0
1
2
0
0
0
1
5
0
6
Note address 091: The download is ENABLED by default. Enter a value of 21 at address 091 to disable modem (21 rings for modem not
accepted by telephone net). To ENABLE enter 01 to 20 at address 091. To enable Instant Modem Answer (Answer Now) enter 01 in
address 092. In use mode; hold-down key 6 then hold-down key 1. ‘A’ is displayed in confirmation.
SET USER CODES:
Address 099 provides setting of user codes 1 to 8.
SET FACTORY DEFAULT:
AV-2008:
In address 200 enter 8 0, program will revert to factory default programming
AV-2005:
In address 200 enter 5 0, program will revert to factory default programming
Display version:
The version (revision) and its date is displayed in installer programming mode by command 200+00