28
New alarm will create a new history event instead of the old one.
4.
0
Shunt
then
1
Siren
Display and Setting of System Time:
Hold down key ‘0’ and then hold-
down key ‘1,’ 3 LEDs will blink. Wait for the display of system time in 4-digit format.
To set new time, hold down key ‘0’ and then hold down key ‘1.’ Do not wait for time display; enter
the new time in 24-hour format. The local clock time is not stored in system memory; clock must be
adjusted after power-up. After power-up system, time is reset to 00:00, ‘h’ will be displayed to
remind user to set time; ‘h’ will disappear after new time is set. If Auto-Arming selected time setting
is possible only in ‘User Programming Mode’, refer to paragraph 3.7.
5.
0
Shunt
then
2
Shunt
Display
Display and Setting of System Date:
Hold down key ‘0’ and then hold-
down key ‘2’; three LEDs are blinking. Enter date: ‘dd mm yy.’ The up and download PC software
displays time and date, along with event history.
The local date is stored in system memory; date must be adjusted after long power-fail.
Years 78 through 99 translated as 1978 to 1999
Years 00 through 77 translated as 2000 to 2077
6.
0
Shunt
then
4
Delay
Delete
Reset Events Memory (history):
Hold down key ‘0’ and then hold
down key ‘4’ to erase all events from memory.
Starting version 2.09: History log cannot be cleared by the user (former command "0" + "4").
Instead, it can be cleared during the installer-programming mode by command 200+04.
7.
0
Shunt
then
5
Chime
Display Last 2 Users:
Hold down key ‘0’ and then hold down key 5 to
display user number and System opening or closing time.
‘o’ is displayed for Opening (Disarming); ‘c’ is displayed for Closing (Arming).
8. Press
0
Shunt
(not hold-down)
and press
9
Reset
(not hold-down), will display ‘-’ to cancel all
Bypassed Zones.
*
#
Keypad Panic
Keys
PANIC BUTTON
Holding down * and # keys will trigger Panic alarm. H will be displayed (zone ‘H’).
To cancel
Hold-Down
function accessed by key [0], [6] and [7],
Hold-Down key 9 (Reset)