SECTION II: INSTALLATION
System planning
When the panel reaches you it will be factory programmed. This is done for testing purposes and for
average installation, if required without first entering to programming. This present program is
referred to as ‘Factory Defaults.’ It is advised that the engineer should be familiar with all the
features and options before attempting to program. Keypad should be specified and ordered
separately (several types available). Default arming code (user 1) is 1,2,3,4. Default programming
code is 1,9,9,4.
For best results please read the manual before installation and programming.
Tips to first time installer
If you are a first time installer, don’t hook up any remote sensors yet. The most common confusion
comes about when the
alarm will refuse to arm
, because a zone is “troubled”. Complete the power
supply, siren, keypad and strobe wiring, and for the moment connect ALL the zone terminals to –V
with loops of wire. This will simulate a system with all zones looped out through closed switches and
no EOL resistors. The alarm is supplied already programmed with an “average” list of settings
(default) and can be used straight away, a few of the program locations may have to be changed to
suit the actual sensors and output devices used.
Read this manual carefully, it looks complicated, but all the information is there
If you are using a PRO panel carefully read the manual supplied with your LCD keypad. LCD and LED
keypads cannot operate in the same system. For AV-2008D (remote DTMF) refer this type appendix
To start with: Hook up the keypad, connect all zones to –V, power-up by applying AC only
In case the keypad displays ‘garbage’ verify the minus (-V) wire connection
Arm and disarm the system, when the Status LED light (not blinking), enter your master code; 1234
Try the hold-down functions. Hold each key for approximately 2 seconds; follow the confirmation letters
in keypad’s display
Set the system time by holding-down key ‘1’ then ‘0’, enter the time in 24 format, this will stop the blinking ‘h’
The default programming is set for siren; the siren is plain speaker horn, if your alarm device requires 12V
to alarm, you have to change the programming to Bell mode
Connect the strobe light to the SLO output (requires programming). The SLO supplies –V during alarm
Make sure you are using the Earth terminal
for Grounding; it’s not a minus terminal
Typing six erroneous codes will lock the keypad keys for 30 seconds, don’t change code for starting
1. MOUNTING
1.1
Control Panel Mounting
Refer to detailed wiring diagram on page 61. Note: ‘h’ is displayed after power-up and upon Arming
to remind user to set the system time; ‘h’ will be removed after time setting, by using keys 0 and 1,
(refer to page 22, 26). Install the panel in a ventilated place, far away from RF transmitters or other
electric noise generators.