27
Translate the display as following:
‘u’ (user number 1 to 8),
‘o’ or ‘c’ - opening or closing
Zone causing alarm will blink twice
tX - Tamper alarm from zone causing the alarm (X)
H - Panic Alarm
Events at AV-701/2 keypad and computer events log displayed as following:
'CE' - Communication to central station failure
'PE' - Keypad locked because Password Error
'Lb' - Low battery
'CC’ - Telephone line fault
Note:
Three lines (
) indicate power fail. During history events AC power fail is displayed.
For example:
01 2 2 _ 2 4 u 1 o 02 2 3 _ 0 5 7 7 03 2 3 _ 3 5 H H 04 0 0 _ 0 8 u 1 c -
Sign then long beep
Event 01
Time
User 1
Opening
Event 2 Time Alarm Zone 7 Event 3 Time Alarm Zone H Event 4 Time User 1 Closing
Display
indicates end of History
Zone No. blinks twice
Figure 6: Alarm Events as Displayed on keypad
During zone number display, keypad display blinks twice to indicate the zone number.
Browsing through Events History
Keys used for browsing:
2
Shunt
Display
Skip forward to next event
8
Program
Skip backward to previous event
5
Chime
Display current event again
9
Reset
Cancel History Event Mode and exit
Upon display of last event, if an attempt is made to move forward (key 2), a blank sign – is displayed,
along with a warning beep indicating that it is the last event. Key 8 may be pressed to move
backward. If no key is pressed, Event History stops and system returns to Use mode.
When starting History Events mode the events are displayed from beginning to end without any
break, until any browsing key is pressed.
During History Events display, browsing system will respond only to alarm or panic. Arming is
denied.
Alarm or Panic during History Events display will quit this mode and system will set to Use
Mode (normal operation mode). Clearer History events are available when using the download.
For easier detailed alarm history, download events log from panel to the remote computer. History
queue log of up to 99 events is displayed at panel keypad and in the
EasyLoad
PC software.
3.
0
Shunt
then
3
Status
Concise History of Tampered Zones:
Hold down key ‘0’ and then hold
down key ‘3’ to display the Tampered zone alarm sequence.