61
Symptom
Possible Cause
Solution
Remote signaling outputs do not
drive (-)
Overload
Incorrect testing
Incorrect programming
Current consumption from
output to load should not be
higher than 300 mA (test
outputs by connecting
voltmeter from output to (+)
Aux. power; upon signaling,
meter should read 12.5 to
13.6 Volts)
Panel’s PCB is getting hot, system
doesn’t function normally
High AC power
Power supply
overloaded or faulty
battery (shorten)
Measure the low AC power,
should not exceed 17V
Try to disconnect sensors,
keypads or other devices that
consume high current
Dialer does not dial on alarm, in spite
of a good line and connection
Programming error
Dialer or communicator time-
out addresses should have a
value greater than ‘0’ (zero).
Try to program ‘default
Program, and dial mode set to
Pulse mode
Keypad sounder beeps in disarm
mode
Hold-down function was
entered, or Day zone
triggered
Arm and then disarm to
cancel chime and fault find
features, or hold-down key ‘9’
to reset day zone alarm
User code is unknown
User forgot the Arming
code
1) Proceed the default codes
restore (if programmed so)
2) Enter to programming
mode address 099. Set new
user code.
3) Refer to ‘Resetting Codes
To Default’ feature, page 51