43
Entry Delay 1 and 2
- To enable two different entries delay period, program selected zone(s) for Entry
Delay 1, and other zones for Entry Delay 2. Cancel entry delay by holding down key 4 prior to Arming.
Program Entry Delay 1 for a maximum of 99 seconds. Entry Delay 2 maximum of 396 seconds (see
Time Outs at addresses 060 and 061).
Addresses: 021 & 022.
Entry/Exit Follower Zone
- Reacts instantly upon detection without previous triggering of delayed
zone. Exit delay affects follower zones. Follower zone acts as delayed zone during exit delay and after
entering via delayed zone. It is recommended to avoid installing magnetic switches for protection of a
follower zone. (They should be used only for entry/exit door).
Address: 023.
Erase ‘Follow-Me’ Number upon Disarming
- After disarming, the system erase (deletes) the Follow-
Me number. If the ‘erase’ feature is not programmed, ‘Follow-Me’ number is stored in System memory
as the first Dialer number. System dials first the communicator number/s (if communicator selected).
Address: 071
Exit Delay
- Determines the delay period (for delayed or follower zones) before zone becoming active.
Countdown starts upon system arming. Maximum exit delay is 396 seconds.
Address: 062.
Exit Delay when Delayed Zones Clear -
Enables Arming of the system only when all delayed zones
are clear. Exit Delay will start the countdown. Applicable when long or variable exit delay is required.
Address: 072.
Fire Zone -
A zone programmed for connection of fire or smoke detector. Alarm sounded in both
Armed and Disarmed modes. Activate the Fire LED. If Fire zone remains troubled after disarming the
system a warning sounder will sound after 10 seconds from disarming (allows the user to repair or
bypass the troubled zone). After another 10 seconds, the alarm will be triggered.
Fire alarm activates siren sound that is differs from the 24H zone or burglary alarm, only if siren speaker
is used. Address: 019.
Fast Response Zone
– A Fast Response zone is set to 100 ms (standard response time is 750 ms). Use
Fast Response zone for connection of shock (inertia) or beam type detectors. The time response for
zones programmed as ‘Fast Response’ is programmed at address 054. Note: Applicable for sensors with
short open time relay.
Warning:
Fast response zones increase the false alarms occurrences
Addresses: 032.
‘Follow-Me’ Number -
Telephone number programmed by user
before Arming, enables user to set a
telephone number to follow him to other locations at an alarm. Addresses: 010.
Forced Opening (Ambush) -
Forced Opening (disarming) is operative only if ‘Report to Central
Station’ is selected (refer to program table address 256). By disarming the system with the opposite