42
Auto Bypass (Instant Zone)
- For automatic bypass of troubled instant zone(s) upon Arming, program
zone(s) as Auto Bypass. Attempting to Arm the system while zone(s) programmed as Auto Bypass Zone
are troubled will activate the Yellow LED on keypad in confirmation that zone is bypassed. Automatic
bypass does not affect Delayed, Follower, Fire, or 24H zones.
Address: 034.
Code ‘8’ as One Time Code -
This feature enables user code no. 8 as one time Arming code. If this
feature is selected, the code will be operative during 30 seconds after Arming with code 8. During the
30 seconds, Code No. 8 will be active for both Arming and Disarming.
Enter ‘8’ at address 071 to
enable this feature.
Day Zone -
Zone programmed as a Day Zone enables alarm from keypad's sounder during daytime
(system is usually disarmed). The day zone will trigger the keypad sounder, and the zone number will
flash on keypad display. To reset Day Zone alarm, hold-down key 9 (reset key).
During Arm mode, this zone will act as burglary zone and will emit an alarm when troubled.
Address: 025.
Delayed Zone
- Zone programmed as a Delay Zone provides exit and entry delay time from arming
moment. See Entry Delay 1 and 2.
Dial Parameters -
Enables adjustment of dialing specifications according to local requirements. The
most critical are the Pulse Make and Pulse Break times (Pulse Dial mode) that may be different in each
area. Steps are by 5 milliseconds (ms), which is sufficient according to tolerance requirements of +/–2
milliseconds. Contact your local Telephone Company for full specifications in your area. Addresses:
080-090.
Dialer Report AC Power Fail
(from Version 2.17C) - Enable this feature by programming 051-7.
When feature enabled system reports AC Fail to user telephone. AC Failure is recognize as rapidly
changing tone sound sent by the system’s dialer. Whenever other events occur, the sound for burglary,
panic or fir events has priority.
When this feature is enabled, the AC power fail event will blinks the Red LED (armed) (same as in the
alarm event). After disarming the system when the AC power fail event occurred and was reported by
the dialer, entering a user code will not Arm the system - it will simply clear the condition (the Red LED
will stop blinking) and will stop the dialer activity. To arm the system re-enter the user code.
Enable Siren Test upon Arming
- A Short beep sounded upon arming, indicating that the system is
armed and siren is operative.
To enable Siren Test upon Arming, enter value ‘1’ in address 070.
Address: 070.
Enable OUT 2 for Smoke Detector
Reset
- After the Smoke Alarm triggering, reset is required.
Pressing key ‘9’ activates OUT #2, which briefly disconnects smoke detector power (via optional relay)
and resets automatically. Address: 071.