450
11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
25.15.1
SMC Setup Register
Name:
SMC_SETUP[0..3]
Address:
0x400E0000 [0], 0x400E0010 [1], 0x400E0020 [2], 0x400E0030 [3], 0x400E0040 [4]
Access:
Read-write
• NWE_SETUP: NWE Setup Length
The NWE signal setup length is defined as:
NWE setup length = (128* NWE_SETUP[5] + NWE_SETUP[4:0]) clock cycles
• NCS_WR_SETUP: NCS Setup Length in WRITE Access
In write access, the NCS signal setup length is defined as:
NCS setup length = (128* NCS_WR_SETUP[5] + NCS_WR_SETUP[4:0]) clock cycles
• NRD_SETUP: NRD Setup Length
The NRD signal setup length is defined in clock cycles as:
NRD setup length = (128* NRD_SETUP[5] + NRD_SETUP[4:0]) clock cycles
• NCS_RD_SETUP: NCS Setup Length in READ Access
In read access, the NCS signal setup length is defined as:
NCS setup length = (128* NCS_RD_SETUP[5] + NCS_RD_SETUP[4:0]) clock cycles
31
30
29
28
27
26
25
24
–
–
NCS_RD_SETUP
23
22
21
20
19
18
17
16
–
–
NRD_SETUP
15
14
13
12
11
10
9
8
–
–
NCS_WR_SETUP
7
6
5
4
3
2
1
0
–
–
NWE_SETUP
Содержание SAM4S Series
Страница 44: ...44 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Страница 412: ...412 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Страница 1105: ...1105 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Страница 1142: ...1142 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 3 100 ball VFBGA Package Drawing ...
Страница 1143: ...1143 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 4 64 lead LQFP Package Drawing ...
Страница 1145: ...1145 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 5 64 lead QFN Package Drawing ...