37.7.25
PWM Fault Clear Register
Name:
PWM_FCR
Address:
0x40020064
Access:
Write-only
• FCLR: Fault Clear (fault input bit varies from 0 to 5)
For each field bit y (fault input number):
0 = No effect.
1 = If bit y of FMOD field is set to 1 and if the fault input y is not at the level defined by the bit y of FPOL field, the fault y
is cleared and becomes inactive (FMOD and FPOL fields belong to
“PWM Fault Mode Register” on page 956
writing this bit to 1 has no effect.
31
30
29
28
27
26
25
24
–
23
22
21
20
19
18
17
16
–
15
14
13
12
11
10
9
8
–
7
6
5
4
3
2
1
0
FCLR