![Atmel SAM4S Series Скачать руководство пользователя страница 270](http://html1.mh-extra.com/html/atmel/sam4s-series/sam4s-series_preliminary-data-sheet_3003408270.webp)
270
11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
14.5.4
Real-time Timer Status Register
Name:
RTT_SR
Address:
0x400E143C
Access:
Read-only
• ALMS: Real-time Alarm Status
0 = The Real-time Alarm has not occurred since the last read of RTT_SR.
1 = The Real-time Alarm occurred since the last read of RTT_SR.
• RTTINC: Real-time Timer Increment
0 = The Real-time Timer has not been incremented since the last read of the RTT_SR.
1 = The Real-time Timer has been incremented since the last read of the RTT_SR.
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
–
–
–
–
15
14
13
12
11
10
9
8
–
–
–
–
–
–
–
–
7
6
5
4
3
2
1
0
–
–
–
–
–
–
RTTINC
ALMS