474
11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
26.5.10
Transfer Status Register
Name:
PERIPH_PTSR
Access:
Read-only
• RXTEN: Receiver Transfer Enable
0 = PDC Receiver channel requests are disabled.
1 = PDC Receiver channel requests are enabled.
• TXTEN: Transmitter Transfer Enable
0 = PDC Transmitter channel requests are disabled.
1 = PDC Transmitter channel requests are enabled.
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
–
–
–
–
15
14
13
12
11
10
9
8
–
–
–
–
–
–
–
TXTEN
7
6
5
4
3
2
1
0
–
–
–
–
–
–
–
RXTEN