1053
11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
40.7.4
ADC Channel Sequence 2 Register
Name:
ADC_SEQR2
Address:
0x4003800C
Access:
Read-write
This register can only be written if the WPEN bit is cleared in
“ADC Write Protect Mode Register” on page 1069
• USCHx: User Sequence Number x
The sequence number x (USCHx) can be programmed by the Channel number CHy where y is the value written in this
field. The allowed range is 0 up to 7. So it is only possible to use the sequencer from CH0 to CH
7.
This register activates only if ADC_MR(USEQ) field is set to ‘1’.
Any USCHx field is taken into account only if ADC_CHSR(CHx) register field reads logical ‘1’ else any value written in
USCHx does not add the corresponding channel in the conversion sequence.
When configuring consecutive fields with the same value, the associated channel is sampled as many time as the number
of consecutive values, this part of the conversion sequence being triggered by a unique event.
Configuring the same value in different fields leads to multiple samples of the same channel during the conversion
sequence. This can be done consecutively, or not, according to user needs.
31
30
29
28
27
26
25
24
–
USCH16
–
USCH15
23
22
21
20
19
18
17
16
–
USCH14
–
USCH13
15
14
13
12
11
10
9
8
–
USCH12
–
USCH11
7
6
5
4
3
2
1
0
–
USCH10
–
USCH9
Содержание SAM4S Series
Страница 44: ...44 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Страница 412: ...412 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Страница 1105: ...1105 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Страница 1142: ...1142 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 3 100 ball VFBGA Package Drawing ...
Страница 1143: ...1143 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 4 64 lead LQFP Package Drawing ...
Страница 1145: ...1145 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 5 64 lead QFN Package Drawing ...